Human EPO (Erythropoietin) CLIA Kit for Quantitative Detection
SPECIFICATIONS
General Information
| Short Description | This human EPO kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes in serum, plasma and other biological fluids. |
| Applications | CLIA |
| Reactivity | Human |
| Sensitivity | 7.5pg/mL |
| Detection Limit | 12.5~800pg/mL |
| Note | FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Product Properties
| Storage Instruction | If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
| Assay Time | 3.5h |
| Detection | Chemiluminescence |
Target Information
| Gene Symbol | EPO |
| Gene ID | 2056 |
| Uniprot ID | EPO_HUMAN |
| Specificity | This kit recognizes Human EPO in samples. No significant cross-reactivity or interference between Human EPO and analogues was observed. |
| Sample Type | Serum, plasma and other biological fluids |
Additional Info
| Tissue Specificity | Produced by kidney or liver of adult mammals and by liver of fetal or neonatal mammals. |
| Function | Hormone involved in the regulation of erythrocyte proliferation and differentiation and the maintenance of a physiological level of circulating erythrocyte mass. Binds to EPOR leading to EPOR dimerization and JAK2 activation thereby activating specific downstream effectors, including STAT1 and STAT3. |
| Protein Name | ErythropoietinEpoetin |
| Database Links | Reactome: R-HSA-1234158Reactome: R-HSA-9006335Reactome: R-HSA-9027276Reactome: R-HSA-9027277Reactome: R-HSA-9027283Reactome: R-HSA-9027284 |
| Cellular Localisation | Secreted |
| Alternative CLIA Names | Erythropoietin CLIA kitEpoetin CLIA kitEPO CLIA kit |
| Specificity | This kit recognizes Human EPO in samples. No significant cross-reactivity or interference between Human EPO and analogues was observed. |
| Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
| Item | Specifications | Storage |
|---|---|---|
| Micro CLIA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
| Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
| Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
| Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
| Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
| Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
| HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
| Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
| Substrate Reagent A | 1 vial, 5 mL | 2-8℃ (Protect from light) |
| Substrate Reagent B | 1 vial, 5 mL | 2-8℃ (Protect from light) |
| Plate Sealer | 5 pieces | |
| Manual | 1 copy | |
| Certificate of Analysis | 1 copy |
| Sample Type | Range (%) | Average Recovery (%) |
|---|---|---|
| Serum(n=8) | 88-102 | 95 |
| EDTA plasma(n=8) | 94-107 | 102 |
| Cell culture media(n=8) | 95-111 | 103 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision | |
|---|---|---|---|---|---|---|
| Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
| n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
| Mean (pg/mL) | 40.84 | 104.28 | 326.11 | 39.08 | 94.62 | 296.04 |
| Standard deviation | 4.14 | 7.36 | 32.71 | 3.56 | 11.07 | 22.11 |
| CV (%) | 10.14 | 7.06 | 10.03 | 9.11 | 11.70 | 7.47 |