Mouse TTR (Transthyretin) CLIA Kit for Quantitative Detection

SPECIFICATIONS
STJC0001472
🚚 Free UK Delivery on orders over £150
Processing The item has been added
Enquire For Bulk Order
✓ 1-Year Performance Guarantee | SDS & Datasheet Included | Expert Tech Support | Covered by St John's Laboratory Guarantee

General Information

Short DescriptionThis mouse TTR kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes in serum, plasma and other biological fluids.
ApplicationsCLIA
ReactivityMouse
Sensitivity0.94ng/mL
Detection Limit1.56~100ng/mL
NoteFOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.

Product Properties

Storage InstructionIf unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time3.5h
DetectionChemiluminescence

Target Information

Gene SymbolTtr
Gene ID22139
Uniprot IDTTHY_MOUSE
SpecificityThis kit recognizes Mouse TTR in samples. No significant cross-reactivity or interference between Mouse TTR and analogues was observed.
Sample TypeSerum, plasma and other biological fluids

Additional Info

Tissue Specificity Detected in plasma (at protein level). Detected in liver.
Post Translational Modifications Sulfonation of the reactive cysteine Cys-30 enhances the stability of the native conformation of TTR, avoiding misassembly of the protein leading to amyloid formation.
Function Thyroid hormone-binding protein. Probably transports thyroxine from the bloodstream to the brain.
Protein Name Transthyretin
Prealbumin
Database Links Reactome: R-MMU-2453902
Reactome: -MMU-6798695
Reactome: -MMU-975634
Cellular Localisation Secreted
Alternative CLIA Names Transthyretin CLIA kit
Prealbumin CLIA kit
Ttr CLIA kit
Specificity This kit recognizes Mouse TTR in samples. No significant cross-reactivity or interference between Mouse TTR and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 86-101 92
EDTA plasma(n=8) 99-112 104
Cell culture media(n=8) 98-112 105

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (ng/mL) 4.81 8.74 35.15 4.42 8.49 37.81
Standard deviation 0.52 1.04 2.58 0.43 0.89 3.55
CV (%) 10.81 11.90 7.34 9.73 10.48 9.39

Citations