• Human TNNI3 (Troponin I, cardiac muscle) CLIA Kit (STJC0000352)

Human TNNI3 (Troponin I, cardiac muscle) CLIA Kit (STJC0000352)

SKU:
STJC0000352

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 46.88pg/mL
Detection Limit: 78.13~5000pg/mL
Short Description: This human TNNI3 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: TNNI3
Gene ID: 7137
Uniprot ID: TNNI3_HUMAN
Specificity: This kit recognizes Human cTn-I/TNNI3 in samples. No significant cross-reactivity or interference between Human cTn-I/TNNI3 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Post Translational Modifications Phosphorylated at Ser-42 and Ser-44 by PRKCE.phosphorylation increases myocardium contractile dysfunction. Phosphorylated at Ser-23 and Ser-24 by PRKD1.phosphorylation reduces myofilament calcium sensitivity. Phosphorylated preferentially at Thr-31. Phosphorylation by STK4/MST1 alters its binding affinity to TNNC1 (cardiac Tn-C) and TNNT2 (cardiac Tn-T).
Function Troponin I is the inhibitory subunit of troponin, the thin filament regulatory complex which confers calcium-sensitivity to striated muscle actomyosin ATPase activity.
Protein Name Troponin I - Cardiac Muscle
Cardiac Troponin I
Database Links Reactome: R-HSA-390522
Reactome: R-HSA-5578775
Alternative CLIA Names Troponin I - Cardiac Muscle CLIA kit
Cardiac Troponin I CLIA kit
TNNI3 CLIA kit
TNNC1 CLIA kit
Specificity This kit recognizes Human cTn-I/TNNI3 in samples. No significant cross-reactivity or interference between Human cTn-I/TNNI3 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 100-116 107
EDTA plasma(n=8) 92-106 99
Cell culture media(n=8) 93-107 98

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 254.53 513.41 1903.30 257.46 557.97 1898.33
Standard deviation 24.89 60.02 156.64 30.05 44.30 184.52
CV (%) 9.78 11.69 8.23 11.67 7.94 9.72
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance