Human MAP Tau (Microtubule Associated Protein Tau/Tau Protein) CLIA Kit for Quantitative Detection

SPECIFICATIONS
STJC0000469
🚚 Free UK Delivery on orders over £150
Processing The item has been added
Enquire For Bulk Order
✓ 1-Year Performance Guarantee | SDS & Datasheet Included | Expert Tech Support | Covered by St John's Laboratory Guarantee

General Information

Short DescriptionThis human MAP Tau kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes in serum, plasma and other biological fluids.
ApplicationsCLIA
ReactivityHuman
Sensitivity3.75pg/mL
Detection Limit6.25~400pg/mL
NoteFOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.

Product Properties

Storage InstructionIf unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time3.5h
DetectionChemiluminescence

Target Information

SpecificityThis kit recognizes Human MAP Tau in samples. No significant cross-reactivity or interference between Human MAP Tau and analogues was observed.
Sample TypeSerum, plasma and other biological fluids

Additional Info

Specificity This kit recognizes Human MAPτ in samples. No significant cross-reactivity or interference between Human MAPτ and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 94-110 101
EDTA plasma(n=8) 92-104 98
Cell culture media(n=8) 92-105 99

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 18.97 38.93 154.43 20.23 42.32 156.66
Standard deviation 2.36 3.99 14.18 2.27 4.63 9.42
CV (%) 12.44 10.25 9.18 11.22 10.94 6.01