Human INS (Insulin) CLIA Kit for Quantitative Detection

SPECIFICATIONS
STJC0000729
🚚 Free UK Delivery on orders over £150
Processing The item has been added
Enquire For Bulk Order
✓ 1-Year Performance Guarantee | SDS & Datasheet Included | Expert Tech Support | Covered by St John's Laboratory Guarantee

General Information

Short DescriptionThis human INS kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes in serum, plasma and other biological fluids.
ApplicationsCLIA
ReactivityHuman
Sensitivity0.38ng/mL
Detection Limit0.63~40ng/mL
NoteFOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.

Product Properties

Storage InstructionIf unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time3.5h
DetectionChemiluminescence

Target Information

Gene SymbolINS
Gene ID3630
Uniprot IDINS_HUMAN
SpecificityThis kit recognizes Human INS in samples. No significant cross-reactivity or interference between Human INS and analogues was observed.
Sample TypeSerum, plasma and other biological fluids

Additional Info

Function Insulin decreases blood glucose concentration. It increases cell permeability to monosaccharides, amino acids and fatty acids. It accelerates glycolysis, the pentose phosphate cycle, and glycogen synthesis in liver.
Protein Name Insulin Cleaved Into - Insulin B Chain - Insulin A Chain
Database Links Reactome: R-HSA-210745
Reactome: R-HSA-264876
Reactome: R-HSA-422085
Reactome: R-HSA-422356
Reactome: R-HSA-6807878
Reactome: R-HSA-6811558
Reactome: R-HSA-74713
Reactome: R-HSA-74749
Reactome: R-HSA-74751
Reactome: R-HSA-74752
Reactome: R-HSA-77387
Reactome: R-HSA-9615017
Reactome: R-HSA-9768919
Reactome: R-HSA-977225
Cellular Localisation Secreted
Alternative CLIA Names Insulin Cleaved Into - Insulin B Chain - Insulin A Chain CLIA kit
INS CLIA kit
Specificity This kit recognizes Human INS in samples. No significant cross-reactivity or interference between Human INS and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 90-101 96
EDTA plasma(n=8) 85-99 92
Cell culture media(n=8) 97-112 103

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (ng/mL) 1.83 6.14 14.27 1.98 6.69 14.09
Standard deviation 0.19 0.56 0.94 0.23 0.74 0.92
CV (%) 10.38 9.12 6.59 11.62 11.06 6.53