• Human COL6A1 (Collagen alpha-1 (VI) chain) CLIA Kit (STJC0000401)

Human COL6A1 (Collagen alpha-1 (VI) chain) CLIA Kit (STJC0000401)

SKU:
STJC0000401

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 0.94ng/mL
Detection Limit: 1.56~100ng/mL
Short Description: This human COL6A1 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: COL6A1
Gene ID: 1291
Uniprot ID: CO6A1_HUMAN
Specificity: This kit recognizes Human COL6 in samples. No significant cross-reactivity or interference between Human COL6 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Post Translational Modifications Prolines at the third position of the tripeptide repeating unit (G-X-Y) are hydroxylated in some or all of the chains.
Function Collagen VI acts as a cell-binding protein.
Protein Name Collagen Alpha-1(Vi Chain
Database Links Reactome: R-HSA-1442490
Reactome: R-HSA-1650814
Reactome: R-HSA-186797
Reactome: R-HSA-2022090
Reactome: R-HSA-216083
Reactome: R-HSA-3000178
Reactome: R-HSA-419037
Reactome: R-HSA-8948216
Cellular Localisation Secreted
Extracellular Space
Extracellular Matrix
Alternative CLIA Names Collagen Alpha-1(Vi Chain CLIA kit
COL6A1 CLIA kit
Specificity This kit recognizes Human COL6 in samples. No significant cross-reactivity or interference between Human COL6 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 93-105 98
EDTA plasma(n=8) 95-110 103
Cell culture media(n=8) 94-107 101

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (ng/mL) 5.13 13.66 45.29 5.18 12.76 46.98
Standard deviation 0.64 1.59 4.32 0.53 1.17 3.71
CV (%) 12.48 11.64 9.54 10.23 9.17 7.90
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance