Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 18.75pg/mL
Detection Limit: 31.25~2000pg/mL
Short Description: This human OCLN kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: OCLN
Gene ID: 100506658
Uniprot ID: OCLN_HUMAN
Specificity: This kit recognizes Human OCLN in samples. No significant cross-reactivity or interference between Human OCLN and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Localized at tight junctions of both epithelial and endothelial cells. Highly expressed in kidney. Not detected in testis.
Post Translational Modifications Dephosphorylated by PTPRJ. The tyrosine phosphorylation on Tyr-398 and Tyr-402 reduces its ability to interact with TJP1. Phosphorylation at Ser-490 also attenuates the interaction with TJP1. (Microbial infection) Cleaved by S.pyogenes SpeB protease.leading to its degradation. Degradation by SpeB promotes bacterial translocation across the host epithelial barrier.
Function May play a role in the formation and regulation of the tight junction (TJ) paracellular permeability barrier. It is able to induce adhesion when expressed in cells lacking tight junctions. (Microbial infection) Acts as a coreceptor for hepatitis C virus (HCV) in hepatocytes.
Protein Name Occludin
Database Links Reactome: R-HSA-351906
Reactome: R-HSA-8935964
Cellular Localisation Cell Membrane
Multi-Pass Membrane Protein
Cell Junction
Tight Junction
Alternative CLIA Names Occludin CLIA kit
OCLN CLIA kit
Specificity This kit recognizes Human OCLN in samples. No significant cross-reactivity or interference between Human OCLN and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 93-108 101
EDTA plasma(n=8) 90-105 96
Cell culture media(n=8) 99-112 104

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 109.15 195.21 975.23 117.29 191.99 954.49
Standard deviation 13.07 22.16 104.84 11.71 22.31 87.81
CV (%) 11.97 11.35 10.75 9.98 11.62 9.20
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance