• Human CRLF1 (Cytokine receptor-like factor 1) CLIA Kit (STJC0000217)

Human CRLF1 (Cytokine receptor-like factor 1) CLIA Kit (STJC0000217)

SKU:
STJC0000217

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 18.75pg/mL
Detection Limit: 31.25~2000pg/mL
Short Description: This human CRLF1 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: CRLF1
Gene ID: 9244
Uniprot ID: CRLF1_HUMAN
Specificity: This kit recognizes Human CRLF1 in samples. No significant cross-reactivity or interference between Human CRLF1 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Highest levels of expression observed in spleen, thymus, lymph node, appendix, bone marrow, stomach, placenta, heart, thyroid and ovary. Strongly expressed also in fetal lung.
Function In complex with CLCF1, forms a heterodimeric neurotropic cytokine that plays a crucial role during neuronal development (Probable). May also play a regulatory role in the immune system.
Protein Name Cytokine Receptor-Like Factor 1
Cytokine-Like Factor 1
Clf-1
Zcytor5
Database Links Reactome: R-HSA-6788467
Reactome: R-HSA-9020956
Cellular Localisation Secreted
Alternative CLIA Names Cytokine Receptor-Like Factor 1 CLIA kit
Cytokine-Like Factor 1 CLIA kit
Clf-1 CLIA kit
Zcytor5 CLIA kit
CRLF1 CLIA kit
UNQ288 CLIA kit
PRO327 CLIA kit
Specificity This kit recognizes Human CRLF1 in samples. No significant cross-reactivity or interference between Human CRLF1 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 86-98 91
EDTA plasma(n=8) 92-105 99
Cell culture media(n=8) 97-111 103

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 96.09 230.64 674.62 103.18 215.23 707.30
Standard deviation 10.54 18.04 44.79 8.78 19.41 67.48
CV (%) 10.97 7.82 6.64 8.51 9.02 9.54
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance