• Human SERPINB2 (Plasminogen activator inhibitor 2) CLIA Kit (STJC0000887)

Human SERPINB2 (Plasminogen activator inhibitor 2) CLIA Kit (STJC0000887)

SKU:
STJC0000887

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 0.19ng/mL
Detection Limit: 0.31~20ng/mL
Short Description: This human SERPINB2 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: SERPINB2
Gene ID: 5055
Uniprot ID: PAI2_HUMAN
Specificity: This kit recognizes Human PAI2 in samples. No significant cross-reactivity or interference between Human PAI2 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Post Translational Modifications The signal sequence is not cleaved.
Function Inhibits urokinase-type plasminogen activator. The monocyte derived PAI-2 is distinct from the endothelial cell-derived PAI-1.
Protein Name Plasminogen Activator Inhibitor 2
Pai-2
Monocyte Arg-Serpin
Placental Plasminogen Activator Inhibitor
Serpin B2
Urokinase Inhibitor
Database Links Reactome: R-HSA-75205
Reactome: R-HSA-8950505
Cellular Localisation Cytoplasm
Secreted
Extracellular Space
Alternative CLIA Names Plasminogen Activator Inhibitor 2 CLIA kit
Pai-2 CLIA kit
Monocyte Arg-Serpin CLIA kit
Placental Plasminogen Activator Inhibitor CLIA kit
Serpin B2 CLIA kit
Urokinase Inhibitor CLIA kit
SERPINB2 CLIA kit
PAI2 CLIA kit
PLANH2 CLIA kit
Specificity This kit recognizes Human PAI2 in samples. No significant cross-reactivity or interference between Human PAI2 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 88-104 95
EDTA plasma(n=8) 90-106 97
Cell culture media(n=8) 88-99 93

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (ng/mL) 1.01 1.74 7.41 1.03 1.90 7.42
Standard deviation 0.11 0.20 0.78 0.13 0.15 0.53
CV (%) 10.89 11.49 10.53 12.62 7.89 7.14
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance