• Human NEFL (Neurofilament light polypeptide) CLIA Kit (STJC0000384)

Human NEFL (Neurofilament light polypeptide) CLIA Kit (STJC0000384)

SKU:
STJC0000384

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 7.5pg/mL
Detection Limit: 12.5~800pg/mL
Short Description: This human NEFL kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: NEFL
Gene ID: 4747
Uniprot ID: NFL_HUMAN
Specificity: This kit recognizes Human NEFL in samples. No significant cross-reactivity or interference between Human NEFL and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Post Translational Modifications O-glycosylated. Phosphorylated in the head and rod regions by the PKC kinase PKN1, leading to the inhibition of polymerization. Ubiquitinated in the presence of TRIM2 and UBE2D1.
Function Neurofilaments usually contain three intermediate filament proteins: NEFL, NEFM, and NEFH which are involved in the maintenance of neuronal caliber. May additionally cooperate with the neuronal intermediate filament proteins PRPH and INA to form neuronal filamentous networks.
Protein Name Neurofilament Light Polypeptide
Nf-L
68 Kda Neurofilament Protein
Neurofilament Triplet L Protein
Database Links Reactome: R-HSA-438066
Reactome: R-HSA-442982
Reactome: R-HSA-5673001
Reactome: R-HSA-9609736
Reactome: R-HSA-9617324
Reactome: R-HSA-9620244
Cellular Localisation Cell Projection
Axon
Cytoplasm
Cytoskeleton
Alternative CLIA Names Neurofilament Light Polypeptide CLIA kit
Nf-L CLIA kit
68 Kda Neurofilament Protein CLIA kit
Neurofilament Triplet L Protein CLIA kit
NEFL CLIA kit
NF68 CLIA kit
NFL CLIA kit
Specificity This kit recognizes Human NEFL in samples. No significant cross-reactivity or interference between Human NEFL and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 95-109 100
EDTA plasma(n=8) 96-111 104
Cell culture media(n=8) 97-108 103

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 42.81 110.42 359.68 45.57 109.06 388.00
Standard deviation 4.76 8.26 23.49 5.50 13.02 28.75
CV (%) 11.12 7.48 6.53 12.07 11.94 7.41
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance