• Human MUC5B (Mucin-5B) CLIA Kit (STJC0000937)

Human MUC5B (Mucin-5B) CLIA Kit (STJC0000937)

SKU:
STJC0000937

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 75pg/mL
Detection Limit: 125~8000pg/mL
Short Description: This human MUC5B kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: MUC5B
Gene ID: 727897
Uniprot ID: MUC5B_HUMAN
Specificity: This kit recognizes Human MUC5B in samples. No significant cross-reactivity or interference between Human MUC5B and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Expressed on surface airway epithelia. Expressed mainly in mucous cells of submucosal glands of airway tissues. Highly expressed in the sublingual gland. Also found in submaxillary glands, endocervix, gall bladder, and pancreas.
Post Translational Modifications Highly glycosylated. C-, N- and O-glycosylated. C-mannosylated in the Cys-rich subdomains probably on the first Trp residue of the WXXW motif. Highly O-glycosylated in the Ser/Thr-rich tandem repeat (TR) region. The repeat region is about 59% O-glycosylated with a high abundance of NeuAc(2)Hex(1)HexNac1-ol.
Function Gel-forming mucin that is thought to contribute to the lubricating and viscoelastic properties of whole saliva and cervical mucus.
Protein Name Mucin-5b
Muc-5b
Cervical Mucin
High Molecular Weight Salivary Mucin Mg1
Mucin-5 Subtype B - Tracheobronchial
Sublingual Gland Mucin
Database Links Reactome: R-HSA-5083625
Reactome: R-HSA-5083632
Reactome: R-HSA-5083636
Reactome: R-HSA-5621480
Reactome: R-HSA-913709
Reactome: R-HSA-977068
Cellular Localisation Secreted
Alternative CLIA Names Mucin-5b CLIA kit
Muc-5b CLIA kit
Cervical Mucin CLIA kit
High Molecular Weight Salivary Mucin Mg1 CLIA kit
Mucin-5 Subtype B - Tracheobronchial CLIA kit
Sublingual Gland Mucin CLIA kit
MUC5B CLIA kit
MUC5 CLIA kit
Specificity This kit recognizes Human MUC5B in samples. No significant cross-reactivity or interference between Human MUC5B and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 87-101 92
EDTA plasma(n=8) 89-101 94
Cell culture media(n=8) 92-107 98

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 373.50 1161.50 3146.62 354.73 1164.49 2991.28
Standard deviation 33.88 100.93 200.75 38.42 117.85 314.08
CV (%) 9.07 8.69 6.38 10.83 10.12 10.50
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance