• Human MT1M (Metallothionein-1M) CLIA Kit (STJC0000328)

Human MT1M (Metallothionein-1M) CLIA Kit (STJC0000328)

SKU:
STJC0000328

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 0.47ng/mL
Detection Limit: 0.78~50ng/mL
Short Description: This human MT1M kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: MT1M
Gene ID: 4499
Uniprot ID: MT1M_HUMAN
Specificity: This kit recognizes Human MT1M in samples. No significant cross-reactivity or interference between Human MT1M and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Function Metallothioneins have a high content of cysteine residues that bind various heavy metals.these proteins are transcriptionally regulated by both heavy metals and glucocorticoids.
Protein Name Metallothionein-1m
Mt-1m
Metallothionein-Im
Mt-Im
Database Links Reactome: R-HSA-5661231
Alternative CLIA Names Metallothionein-1m CLIA kit
Mt-1m CLIA kit
Metallothionein-Im CLIA kit
Mt-Im CLIA kit
MT1M CLIA kit
MT1K CLIA kit
Specificity This kit recognizes Human MT1M in samples. No significant cross-reactivity or interference between Human MT1M and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 98-110 105
EDTA plasma(n=8) 94-107 102
Cell culture media(n=8) 98-113 104

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (ng/mL) 2.55 7.23 20.15 2.57 7.60 18.28
Standard deviation 0.24 0.85 1.67 0.23 0.65 2.06
CV (%) 9.41 11.76 8.29 8.95 8.55 11.27
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance