Applications: |
CLIA |
Reactivity: |
Human |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
18.75pg/mL |
Detection Limit: |
31.25~2000pg/mL |
Short Description: |
This human HAVCR1 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes. |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
Assay Time: |
3.5h |
Detection: |
Chemiluminescence |
Gene Symbol: |
HAVCR1 |
Gene ID: |
26762 |
Uniprot ID: |
HAVR1_HUMAN |
Specificity: |
This kit recognizes Human KIM-1 in samples. No significant cross-reactivity or interference between Human KIM-1 and analogues was observed. |
Sample Type: |
Serum, plasma and other biological fluids |
Tissue Specificity | Widely expressed, with highest levels in kidney and testis. Expressed by activated CD4+ T-cells during the development of helper T-cells responses. |
Post Translational Modifications | Ubiquitinated at two lysine residues Lys-338 and Lys-346 on its cytoplasmic domain. Ubiquitination promotes receptor endocytosis and target receptors for lysosomal degradation and termination of receptor signaling. (Microbial infection) Ubiquitination is required for Dengue virus endocytosis. |
Function | Phosphatidylserine receptor that plays an important functional role in regulatory B-cells homeostasis including generation, expansion and suppressor functions. As P-selectin/SELPLG ligand, plays a specialized role in activated but not naive T-cell trafficking during inflammatory responses. Controls thereby T-cell accumulation in the inflamed central nervous system (CNS) and the induction of autoimmune disease. Regulates also expression of various anti-inflammatory cytokines and co-inhibitory ligands including IL10. Acts as regulator of T-cell proliferation. May play a role in kidney injury and repair. (Microbial infection) Acts as a receptor for Hepatitis A virus. (Microbial infection) Acts as a receptor for Ebolavirus and Marburg virus by binding exposed phosphatidyl-serine at the surface of virion membrane. Serves as a dual receptor for Ebolavirus by also interacting with envelope glycoprotein GP. (Microbial infection) Acts as a receptor for Dengue virus by binding exposed phosphatidyl-serine at the surface of virion membrane. TIM1 and Dengue virus are co-internalized during virus entry. (Microbial infection) Acts as a receptor for Zika virus by binding to envelope protein E. (Microbial infection) Plays a positive role in Chikungunya virus cell entry. |
Protein Name | Hepatitis A Virus Cellular Receptor 1Havcr-1Kidney Injury Molecule 1Kim-1T-Cell Immunoglobulin And Mucin Domain-Containing Protein 1Timd-1T-Cell Immunoglobulin Mucin Receptor 1TimTim-1T-Cell Membrane Protein 1Cd Antigen Cd365 |
Database Links | Reactome: R-HSA-9694614 |
Cellular Localisation | Cell MembraneSingle-Pass Type I Membrane Protein |
Alternative CLIA Names | Hepatitis A Virus Cellular Receptor 1 CLIA kitHavcr-1 CLIA kitKidney Injury Molecule 1 CLIA kitKim-1 CLIA kitT-Cell Immunoglobulin And Mucin Domain-Containing Protein 1 CLIA kitTimd-1 CLIA kitT-Cell Immunoglobulin Mucin Receptor 1 CLIA kitTim CLIA kitTim-1 CLIA kitT-Cell Membrane Protein 1 CLIA kitCd Antigen Cd365 CLIA kitHAVCR1 CLIA kitKIM1 CLIA kitTIM1 CLIA kitTIMD1 CLIA kit |
Specificity | This kit recognizes Human KIM-1 in samples. No significant cross-reactivity or interference between Human KIM-1 and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro CLIA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent A | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Substrate Reagent B | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 90-105 | 96 |
EDTA plasma(n=8) | 94-110 | 100 |
Cell culture media(n=8) | 97-111 | 103 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (pg/mL) | 94.14 | 183.76 | 955.58 | 98.23 | 189.21 | 1032.40 |
Standard deviation | 7.67 | 15.91 | 66.03 | 12.76 | 20.64 | 85.38 |
CV (%) | 8.15 | 8.66 | 6.91 | 12.99 | 10.91 | 8.27 |
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance