• Human FGB (Fibrinogen beta chain) CLIA Kit (STJC0000891)

Human FGB (Fibrinogen beta chain) CLIA Kit (STJC0000891)

SKU:
STJC0000891

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 0.19ng/mL
Detection Limit: 0.31~20ng/mL
Short Description: This human FGB kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: FGB
Gene ID: 2244
Uniprot ID: FIBB_HUMAN
Specificity: This kit recognizes Human FG Beta in samples. No significant cross-reactivity or interference between Human FG Beta and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Detected in blood plasma (at protein level).
Post Translational Modifications Conversion of fibrinogen to fibrin is triggered by thrombin, which cleaves fibrinopeptides A and B from alpha and beta chains, and thus exposes the N-terminal polymerization sites responsible for the formation of the soft clot. The soft clot is converted into the hard clot by factor XIIIA which catalyzes the epsilon-(gamma-glutamyl)lysine cross-linking between gamma chains (stronger) and between alpha chains (weaker) of different monomers.
Function Cleaved by the protease thrombin to yield monomers which, together with fibrinogen alpha (FGA) and fibrinogen gamma (FGG), polymerize to form an insoluble fibrin matrix. Fibrin has a major function in hemostasis as one of the primary components of blood clots. In addition, functions during the early stages of wound repair to stabilize the lesion and guide cell migration during re-epithelialization. Was originally thought to be essential for platelet aggregation, based on in vitro studies using anticoagulated blood. However subsequent studies have shown that it is not absolutely required for thrombus formation in vivo. Enhances expression of SELP in activated platelets. Maternal fibrinogen is essential for successful pregnancy. Fibrin deposition is also associated with infection, where it protects against IFNG-mediated hemorrhage. May also facilitate the antibacterial immune response via both innate and T-cell mediated pathways.
Protein Name Fibrinogen Beta Chain Cleaved Into - Fibrinopeptide B - Fibrinogen Beta Chain
Database Links Reactome: R-HSA-114608
Reactome: R-HSA-1236974
Reactome: R-HSA-140875
Reactome: R-HSA-166058
Reactome: R-HSA-216083
Reactome: R-HSA-354192
Reactome: R-HSA-354194
Reactome: R-HSA-372708
Reactome: R-HSA-5602498
Reactome: R-HSA-5603041
Reactome: R-HSA-5674135
Reactome: R-HSA-5686938
Reactome: R-HSA-6802946
Reactome: R-HSA-6802948
Reactome: R-HSA-6802952
Reactome: R-HSA-6802955
Reactome: R-HSA-9649948
Reactome: R-HSA-9656223
Cellular Localisation Secreted
Alternative CLIA Names Fibrinogen Beta Chain Cleaved Into - Fibrinopeptide B - Fibrinogen Beta Chain CLIA kit
FGB CLIA kit
Specificity This kit recognizes Human FGβ in samples. No significant cross-reactivity or interference between Human FGβ and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 93-107 101
EDTA plasma(n=8) 88-104 95
Cell culture media(n=8) 94-110 100

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (ng/mL) 0.92 2.57 7.05 0.87 2.55 6.99
Standard deviation 0.09 0.19 0.50 0.10 0.24 0.78
CV (%) 9.78 7.39 7.09 11.49 9.41 11.16
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance