Applications: |
CLIA |
Reactivity: |
Human |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
0.19ng/mL |
Detection Limit: |
0.31~20ng/mL |
Short Description: |
This human FGB kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes. |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
Assay Time: |
3.5h |
Detection: |
Chemiluminescence |
Gene Symbol: |
FGB |
Gene ID: |
2244 |
Uniprot ID: |
FIBB_HUMAN |
Specificity: |
This kit recognizes Human FG Beta in samples. No significant cross-reactivity or interference between Human FG Beta and analogues was observed. |
Sample Type: |
Serum, plasma and other biological fluids |
Tissue Specificity | Detected in blood plasma (at protein level). |
Post Translational Modifications | Conversion of fibrinogen to fibrin is triggered by thrombin, which cleaves fibrinopeptides A and B from alpha and beta chains, and thus exposes the N-terminal polymerization sites responsible for the formation of the soft clot. The soft clot is converted into the hard clot by factor XIIIA which catalyzes the epsilon-(gamma-glutamyl)lysine cross-linking between gamma chains (stronger) and between alpha chains (weaker) of different monomers. |
Function | Cleaved by the protease thrombin to yield monomers which, together with fibrinogen alpha (FGA) and fibrinogen gamma (FGG), polymerize to form an insoluble fibrin matrix. Fibrin has a major function in hemostasis as one of the primary components of blood clots. In addition, functions during the early stages of wound repair to stabilize the lesion and guide cell migration during re-epithelialization. Was originally thought to be essential for platelet aggregation, based on in vitro studies using anticoagulated blood. However subsequent studies have shown that it is not absolutely required for thrombus formation in vivo. Enhances expression of SELP in activated platelets. Maternal fibrinogen is essential for successful pregnancy. Fibrin deposition is also associated with infection, where it protects against IFNG-mediated hemorrhage. May also facilitate the antibacterial immune response via both innate and T-cell mediated pathways. |
Protein Name | Fibrinogen Beta Chain Cleaved Into - Fibrinopeptide B - Fibrinogen Beta Chain |
Database Links | Reactome: R-HSA-114608Reactome: R-HSA-1236974Reactome: R-HSA-140875Reactome: R-HSA-166058Reactome: R-HSA-216083Reactome: R-HSA-354192Reactome: R-HSA-354194Reactome: R-HSA-372708Reactome: R-HSA-5602498Reactome: R-HSA-5603041Reactome: R-HSA-5674135Reactome: R-HSA-5686938Reactome: R-HSA-6802946Reactome: R-HSA-6802948Reactome: R-HSA-6802952Reactome: R-HSA-6802955Reactome: R-HSA-9649948Reactome: R-HSA-9656223 |
Cellular Localisation | Secreted |
Alternative CLIA Names | Fibrinogen Beta Chain Cleaved Into - Fibrinopeptide B - Fibrinogen Beta Chain CLIA kitFGB CLIA kit |
Specificity | This kit recognizes Human FGβ in samples. No significant cross-reactivity or interference between Human FGβ and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro CLIA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent A | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Substrate Reagent B | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 93-107 | 101 |
EDTA plasma(n=8) | 88-104 | 95 |
Cell culture media(n=8) | 94-110 | 100 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (ng/mL) | 0.92 | 2.57 | 7.05 | 0.87 | 2.55 | 6.99 |
Standard deviation | 0.09 | 0.19 | 0.50 | 0.10 | 0.24 | 0.78 |
CV (%) | 9.78 | 7.39 | 7.09 | 11.49 | 9.41 | 11.16 |
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance