• Human DBH (Dopamine beta-hydroxylase) CLIA Kit (STJC0000559)

Human DBH (Dopamine beta-hydroxylase) CLIA Kit (STJC0000559)

SKU:
STJC0000559

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 0.19ng/mL
Detection Limit: 0.31~20ng/mL
Short Description: This human DBH kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: DBH
Gene ID: 1621
Uniprot ID: DOPO_HUMAN
Specificity: This kit recognizes Human D Beta H in samples. No significant cross-reactivity or interference between Human D Beta H and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Post Translational Modifications N-glycosylated. Proteolytic cleavage after the membrane-anchor leads to the release of the soluble form.
Function Catalyzes the hydroxylation of dopamine to noradrenaline (also known as norepinephrine), and is thus vital for regulation of these neurotransmitters.
Protein Name Dopamine Beta-Hydroxylase
Dopamine Beta-Monooxygenase Cleaved Into - Soluble Dopamine Beta-Hydroxylase
Database Links Reactome: R-HSA-209905
Cellular Localisation Soluble Dopamine Beta-Hydroxylase: Cytoplasmic Vesicle
Secretory Vesicle Lumen
Cytoplasmic Vesicle
Secretory Vesicle
Chromaffin Granule Lumen
Secreted
Secretory Vesicle Membrane
Single-Pass Type Ii Membrane Protein
Chromaffin Granule Membrane
Alternative CLIA Names Dopamine Beta-Hydroxylase CLIA kit
Dopamine Beta-Monooxygenase Cleaved Into - Soluble Dopamine Beta-Hydroxylase CLIA kit
DBH CLIA kit
Specificity This kit recognizes Human DβH in samples. No significant cross-reactivity or interference between Human DβH and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 93-107 101
EDTA plasma(n=8) 99-111 105
Cell culture media(n=8) 90-106 97

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (ng/mL) 0.92 2.22 6.94 0.86 2.43 7.09
Standard deviation 0.12 0.18 0.80 0.11 0.23 0.48
CV (%) 13.04 8.11 11.53 12.79 9.47 6.77
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance