Applications: |
ELISA |
Reactivity: |
Human |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
0.62 pg/mL |
Detection Limit: |
1.56-100 pg/mL |
Short Description: |
This CTACK Sandwich ELISA is an in-vitro enzyme-linked immunosorbent assay for the measurement of samples in human serum, plasma and other biological fluids. |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
Assay Time: |
3.5h |
Detection: |
Colormetric |
Gene Symbol: |
CCL27 |
Gene ID: |
10850 |
Uniprot ID: |
CCL27_HUMAN |
Specificity: |
This kit recognizes Human CTACK in samples. No significant cross-reactivity or interference between Human CTACK and analogues was observed. |
Sample Type: |
serum, plasma and other biological fluids |
Tissue Specificity | Testis, thymus, placenta, ovary and skin. |
Function | Chemotactic factor that attracts skin-associated memory T-lymphocytes. May play a role in mediating homing of lymphocytes to cutaneous sites. Binds to CCR10. |
Protein Name | C-C Motif Chemokine 27Cc Chemokine IlcCutaneous T-Cell-Attracting ChemokineCtackEskineIl-11 R-Alpha-Locus ChemokineSkinkineSmall-Inducible Cytokine A27 |
Database Links | Reactome: R-HSA-380108Reactome: R-HSA-418594 |
Cellular Localisation | Secreted |
Alternative ELISA Names | C-C Motif Chemokine 27 ELISA kitCc Chemokine Ilc ELISA kitCutaneous T-Cell-Attracting Chemokine ELISA kitCtack ELISA kitEskine ELISA kitIl-11 R-Alpha-Locus Chemokine ELISA kitSkinkine ELISA kitSmall-Inducible Cytokine A27 ELISA kitCCL27 ELISA kitILC ELISA kitSCYA27 ELISA kit |
Specificity | This kit recognizes Human CTACK in samples. No significant cross-reactivity or interference between Human CTACK and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro ELISA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent | 1 vial, 10 mL | 2-8℃ (Protect from light) |
Stop Solution | 1 vial, 10 mL | 2-8°C |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 89-103 | 94 |
EDTA plasma (n=8) | 92-103 | 98 |
Cell culture media (n=8) | 94-107 | 101 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (pg/mL) | 5.36 | 8.56 | 38.57 | 5.54 | 8.19 | 38.27 |
Standard deviation | 0.29 | 0.43 | 1.89 | 0.29 | 0.40 | 2.03 |
CV (%) | 5.37 | 5.03 | 4.91 | 5.22 | 4.94 | 5.31 |
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance