Applications: |
CLIA |
Reactivity: |
Human |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
18.75pg/mL |
Detection Limit: |
31.25~2000pg/mL |
Short Description: |
This human COL14A1 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes. |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
Assay Time: |
3.5h |
Detection: |
Chemiluminescence |
Gene Symbol: |
COL14A1 |
Gene ID: |
7373 |
Uniprot ID: |
COEA1_HUMAN |
Specificity: |
This kit recognizes Human COL14 in samples. No significant cross-reactivity or interference between Human COL14 and analogues was observed. |
Sample Type: |
Serum, plasma and other biological fluids |
Post Translational Modifications | Lysines at the third position of the tripeptide repeating unit (G-X-Y) are hydroxylated in all cases and bind carbohydrates. Prolines at the third position of the tripeptide repeating unit (G-X-Y) are hydroxylated in some or all of the chains. May contain numerous cysteine residues involved in inter- and intramolecular disulfide bonding. |
Function | Plays an adhesive role by integrating collagen bundles. It is probably associated with the surface of interstitial collagen fibrils via COL1. The COL2 domain may then serve as a rigid arm which sticks out from the fibril and protrudes the large N-terminal globular domain into the extracellular space, where it might interact with other matrix molecules or cell surface receptors. |
Protein Name | Collagen Alpha-1(Xiv ChainUndulin |
Database Links | Reactome: R-HSA-1442490Reactome: R-HSA-1650814Reactome: R-HSA-2022090Reactome: R-HSA-8948216 |
Cellular Localisation | SecretedExtracellular SpaceExtracellular Matrix |
Alternative CLIA Names | Collagen Alpha-1(Xiv Chain CLIA kitUndulin CLIA kitCOL14A1 CLIA kitUND CLIA kit |
Specificity | This kit recognizes Human COL14 in samples. No significant cross-reactivity or interference between Human COL14 and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro CLIA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent A | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Substrate Reagent B | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 91-103 | 96 |
EDTA plasma(n=8) | 95-106 | 100 |
Cell culture media(n=8) | 87-99 | 92 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (pg/mL) | 99.16 | 197.00 | 896.62 | 105.11 | 203.89 | 841.72 |
Standard deviation | 11.62 | 14.74 | 98.90 | 11.85 | 24.14 | 72.14 |
CV (%) | 11.72 | 7.48 | 11.03 | 11.27 | 11.84 | 8.57 |
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance