Applications: |
CLIA |
Reactivity: |
Human |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
37.5pg/mL |
Detection Limit: |
62.5~4000pg/mL |
Short Description: |
This human ANXA5 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes. |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
Assay Time: |
3.5h |
Detection: |
Chemiluminescence |
Gene Symbol: |
ANXA5 |
Gene ID: |
308 |
Uniprot ID: |
ANXA5_HUMAN |
Specificity: |
This kit recognizes Human ANXA5 in samples. No significant cross-reactivity or interference between Human ANXA5 and analogues was observed. |
Sample Type: |
Serum, plasma and other biological fluids |
Post Translational Modifications | S-nitrosylation is induced by interferon-gamma and oxidatively-modified low-densitity lipoprotein (LDL(ox)) possibly implicating the iNOS-S100A8/9 transnitrosylase complex. |
Function | This protein is an anticoagulant protein that acts as an indirect inhibitor of the thromboplastin-specific complex, which is involved in the blood coagulation cascade. |
Protein Name | Annexin A5Anchorin CiiAnnexin VAnnexin-5Calphobindin ICpb-IEndonexin IiLipocortin VPlacental Anticoagulant Protein 4Pp4Placental Anticoagulant Protein IPap-IThromboplastin InhibitorVascular Anticoagulant-AlphaVac-Alpha |
Database Links | Reactome: R-HSA-114608 |
Alternative CLIA Names | Annexin A5 CLIA kitAnchorin Cii CLIA kitAnnexin V CLIA kitAnnexin-5 CLIA kitCalphobindin I CLIA kitCpb-I CLIA kitEndonexin Ii CLIA kitLipocortin V CLIA kitPlacental Anticoagulant Protein 4 CLIA kitPp4 CLIA kitPlacental Anticoagulant Protein I CLIA kitPap-I CLIA kitThromboplastin Inhibitor CLIA kitVascular Anticoagulant-Alpha CLIA kitVac-Alpha CLIA kitANXA5 CLIA kitANX5 CLIA kitENX2 CLIA kitPP4 CLIA kit |
Specificity | This kit recognizes Human ANXA5 in samples. No significant cross-reactivity or interference between Human ANXA5 and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro CLIA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent A | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Substrate Reagent B | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 93-106 | 99 |
EDTA plasma(n=8) | 86-100 | 92 |
Cell culture media(n=8) | 94-107 | 102 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (pg/mL) | 198.97 | 362.03 | 1960.13 | 204.27 | 395.76 | 1829.49 |
Standard deviation | 24.21 | 33.42 | 214.63 | 23.92 | 32.21 | 140.14 |
CV (%) | 12.17 | 9.23 | 10.95 | 11.71 | 8.14 | 7.66 |
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance