|  Function  |   Terminates signal transduction at the neuromuscular junction by rapid hydrolysis of the acetylcholine released into the synaptic cleft.  |  
  |  Protein Name  |   AcetylcholinesteraseAche  |  
  |  Cellular Localisation  |   SynapseSecretedCell MembranePeripheral Membrane ProteinIsoform H: Cell MembraneLipid-AnchorGpi-AnchorExtracellular Side  |  
  |  Alternative ELISA Names  |   Acetylcholinesterase ELISA kitAche ELISA kitAche ELISA kit  |  
  |  Specificity  |   This kit recognizes Rat AChE in samples. No significant cross-reactivity or interference between Rat AChE and analogues was observed.  |  
  |  Reproducibility  |   Both intra-CV and inter-CV are  |  
 
Information sourced from Uniprot.org
   |  Item  |   Specifications  |   Storage  |  
  |  Micro ELISA Plate (Dismountable)  |   96T: 8 wells ×12 strips strips  |   -20℃, 6 months  |  
  |  Reference Standard  |   96T: 2 vials 48T: 1 vial  |   -20℃, 6 months  |  
  |  Concentrated Biotinylated Detection Ab (100×)  |   96T: 1 vial, 120 μL 60 μL  |   -20℃, 6 months  |  
  |  Concentrated HRP Conjugate (100×)  |   96T: 1 vial, 120 μL 60 μL  |   -20℃ (Protect from light), 6 months  |  
  |  Reference Standard & Sample Diluent  |   1 vial, 20 mL  |   2-8°C, 6 months  |  
  |  Biotinylated Detection Ab Diluent  |   1 vial, 14 mL  |   2-8°C, 6 months  |  
  |  HRP Conjugate Diluent  |   1 vial, 14 mL  |   2-8°C, 6 months  |  
  |  Concentrated Wash Buffer (25×)  |   1 vial, 30 mL  |   2-8°C, 6 months  |  
  |  Substrate Reagent  |   1 vial, 10 mL  |   2-8℃ (Protect from light)  |  
  |  Stop Solution  |   1 vial, 10 mL  |   2-8°C  |  
  |  Plate Sealer  |   5 pieces  |    |  
  |  Manual  |   1 copy  |    |  
  |  Certificate of Analysis  |   1 copy  |    |  
 
   |  Sample Type  |   Range (%)  |   Average Recovery (%)  |  
  |  Serum(n=8)  |   92-103  |   97  |  
  |  EDTA plasma (n=8)  |   89-99  |   94  |  
  |  Cell culture media (n=8)  |   90-106  |   97  |  
 
   |   |   Intra-assay Precision  |   Intra-assay Precision  |   Intra-assay Precision  |   Inter-assay Precision  |   Inter-assay Precision  |   Inter-assay Precision  |  
  |  Sample  |   1.00  |   2.00  |   3.00  |   1.00  |   2.00  |   3.00  |  
  |  n  |   20.00  |   20.00  |   20.00  |   20.00  |   20.00  |   20.00  |  
  |  Mean (ng/mL)  |   2.43  |   7.13  |   17.70  |   2.43  |   7.84  |   16.22  |  
  |  Standard deviation  |   0.13  |   0.29  |   0.91  |   0.13  |   0.42  |   0.57  |  
  |  CV (%)  |   5.35  |   4.07  |   5.14  |   5.35  |   5.36  |   3.51  |