Applications: |
CLIA |
Reactivity: |
Mouse |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
9.38pg/mL |
Detection Limit: |
15.63~1000pg/mL |
Short Description: |
This mouse IFNa kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes. |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
Assay Time: |
3.5h |
Detection: |
Chemiluminescence |
Gene Symbol: |
Ifna2Ifna1 |
Uniprot ID: |
IFNA2_MOUSEIFNA1_MOUSE |
Specificity: |
This kit recognizes Mouse IFN Alpha in samples. No significant cross-reactivity or interference between Mouse IFN Alpha and analogues was observed. |
Sample Type: |
Serum, plasma and other biological fluids |
Tissue Specificity | |
Alternative CLIA Names | Interferon Alpha-2 CLIA kitIfn-Alpha-2 CLIA kitIfna2 CLIA kitInterferon Alpha-1 CLIA kitIfn-Alpha-1 CLIA kitIfna1 CLIA kit |
Specificity | This kit recognizes Mouse IFNα in samples. No significant cross-reactivity or interference between Mouse IFNα and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro CLIA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent A | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Substrate Reagent B | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 84-95 | 91 |
EDTA plasma(n=8) | 96-104 | 100 |
Cell culture media(n=8) | 92-98 | 95 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (pg/mL) | 48.02 | 106.47 | 491.93 | 47.91 | 119.21 | 437.55 |
Standard deviation | 2.82 | 5.21 | 22.68 | 2.69 | 5.41 | 18.73 |
CV (%) | 5.87 | 4.89 | 4.61 | 5.61 | 4.54 | 4.28 |
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance