Mouse IFNa (Interferon Alpha) CLIA Kit (STJC0001981)

SKU:
STJC0001981

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Mouse
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 9.38pg/mL
Detection Limit: 15.63~1000pg/mL
Short Description: This mouse IFNa kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: Ifna2
Ifna1
Uniprot ID: IFNA2_MOUSE
IFNA1_MOUSE
Specificity: This kit recognizes Mouse IFN Alpha in samples. No significant cross-reactivity or interference between Mouse IFN Alpha and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity
Alternative CLIA Names Interferon Alpha-2 CLIA kit
Ifn-Alpha-2 CLIA kit
Ifna2 CLIA kit
Interferon Alpha-1 CLIA kit
Ifn-Alpha-1 CLIA kit
Ifna1 CLIA kit
Specificity This kit recognizes Mouse IFNα in samples. No significant cross-reactivity or interference between Mouse IFNα and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 84-95 91
EDTA plasma(n=8) 96-104 100
Cell culture media(n=8) 92-98 95

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 48.02 106.47 491.93 47.91 119.21 437.55
Standard deviation 2.82 5.21 22.68 2.69 5.41 18.73
CV (%) 5.87 4.89 4.61 5.61 4.54 4.28
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance