Applications: |
CLIA |
Reactivity: |
Human |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
18.75pg/mL |
Detection Limit: |
31.25~2000pg/mL |
Short Description: |
This human SPTAN1 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes. |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
Assay Time: |
3.5h |
Detection: |
Chemiluminescence |
Gene Symbol: |
SPTAN1 |
Gene ID: |
6709 |
Uniprot ID: |
SPTN1_HUMAN |
Specificity: |
This kit recognizes Human SPTAN1 in samples. No significant cross-reactivity or interference between Human SPTAN1 and analogues was observed. |
Sample Type: |
Serum, plasma and other biological fluids |
Post Translational Modifications | Phosphorylation of Tyr-1176 decreases sensitivity to cleavage by calpain in vitro. |
Function | Fodrin, which seems to be involved in secretion, interacts with calmodulin in a calcium-dependent manner and is thus candidate for the calcium-dependent movement of the cytoskeleton at the membrane. |
Protein Name | Spectrin Alpha Chain - Non-Erythrocytic 1Alpha-Ii SpectrinFodrin Alpha ChainSpectrin - Non-Erythroid Alpha Subunit |
Database Links | Reactome: R-HSA-264870Reactome: R-HSA-373753Reactome: R-HSA-375165Reactome: R-HSA-445095Reactome: R-HSA-5673001Reactome: R-HSA-6798695Reactome: R-HSA-6807878Reactome: R-HSA-9013420Reactome: R-HSA-9013424Reactome: R-HSA-9662360Reactome: R-HSA-9662361 |
Cellular Localisation | CytoplasmCytoskeletonCell CortexExpressed Along The Cell Membrane In Podocytes And Presumptive Tubule Cells During Glomerulogenesis And Is Expressed Along Lateral Cell Margins In Tubule Cells |
Alternative CLIA Names | Spectrin Alpha Chain - Non-Erythrocytic 1 CLIA kitAlpha-Ii Spectrin CLIA kitFodrin Alpha Chain CLIA kitSpectrin - Non-Erythroid Alpha Subunit CLIA kitSPTAN1 CLIA kitNEAS CLIA kitSPTA2 CLIA kit |
Specificity | This kit recognizes Human SPTAN1 in samples. No significant cross-reactivity or interference between Human SPTAN1 and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro CLIA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent A | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Substrate Reagent B | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 98-116 | 106 |
EDTA plasma(n=8) | 92-103 | 97 |
Cell culture media(n=8) | 86-97 | 91 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (pg/mL) | 96.49 | 197.89 | 674.08 | 92.88 | 196.13 | 734.46 |
Standard deviation | 11.86 | 15.91 | 54.33 | 10.39 | 21.48 | 76.97 |
CV (%) | 12.29 | 8.04 | 8.06 | 11.19 | 10.95 | 10.48 |
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance