Applications: |
CLIA |
Reactivity: |
Human |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
9.38pg/mL |
Detection Limit: |
15.63~1000pg/mL |
Short Description: |
This human MUC5AC kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes. |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
Assay Time: |
3.5h |
Detection: |
Chemiluminescence |
Gene Symbol: |
MUC5AC |
Gene ID: |
4586 |
Uniprot ID: |
MUC5A_HUMAN |
Specificity: |
This kit recognizes Human MUC5AC in samples. No significant cross-reactivity or interference between Human MUC5AC and analogues was observed. |
Sample Type: |
Serum, plasma and other biological fluids |
Tissue Specificity | Highly expressed in surface mucosal cells of respiratory tract and stomach epithelia. Overexpressed in a number of carcinomas. Also expressed in Barrett's esophagus epithelium and in the proximal duodenum. |
Post Translational Modifications | C-, O- and N-glycosylated. O-glycosylated on the second and last Thr of the Thr-/Ser-rich tandem repeats TTPSPVPTTSTTSA. One form of glycosylation is also known as Lewis B (LeB) blood group antigen, a tetrasaccharide consisting of N-acetylglucosamine having a fucosyl residue attached. It has a role as an epitope and antigen and functions as a receptor for H.pylori binding and facilitates infection. C-mannosylation in the Cys-rich subdomains may be required for proper folding of these regions and for export from the endoplasmic reticulum during biosynthesis. Proteolytic cleavage in the C-terminal is initiated early in the secretory pathway and does not involve a serine protease. The extent of cleavage is increased in the acidic parts of the secretory pathway. Cleavage generates a reactive group which could link the protein to a primary amide. |
Function | Gel-forming glycoprotein of gastric and respiratory tract epithelia that protects the mucosa from infection and chemical damage by binding to inhaled microorganisms and particles that are subsequently removed by the mucociliary system. Interacts with H.pylori in the gastric epithelium, Barrett's esophagus as well as in gastric metaplasia of the duodenum (GMD). |
Protein Name | Mucin-5acMuc-5acGastric MucinMajor Airway GlycoproteinMucin-5 Subtype Ac - TracheobronchialTracheobronchial MucinTbm |
Database Links | Reactome: R-HSA-5083625Reactome: R-HSA-5083632Reactome: R-HSA-5083636Reactome: R-HSA-5621480Reactome: R-HSA-913709Reactome: R-HSA-977068 |
Cellular Localisation | Secreted |
Alternative CLIA Names | Mucin-5ac CLIA kitMuc-5ac CLIA kitGastric Mucin CLIA kitMajor Airway Glycoprotein CLIA kitMucin-5 Subtype Ac - Tracheobronchial CLIA kitTracheobronchial Mucin CLIA kitTbm CLIA kitMUC5AC CLIA kitMUC5 CLIA kit |
Specificity | This kit recognizes Human MUC5AC in samples. No significant cross-reactivity or interference between Human MUC5AC and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro CLIA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent A | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Substrate Reagent B | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 98-114 | 104 |
EDTA plasma(n=8) | 97-110 | 105 |
Cell culture media(n=8) | 100-114 | 107 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (pg/mL) | 53.62 | 107.89 | 352.39 | 52.64 | 114.80 | 336.15 |
Standard deviation | 6.40 | 9.89 | 31.50 | 6.47 | 10.39 | 21.04 |
CV (%) | 11.94 | 9.17 | 8.94 | 12.29 | 9.05 | 6.26 |
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance