• Human COL7A1 (Collagen alpha-1 (VII) chain) CLIA Kit (STJC0000407)

Human COL7A1 (Collagen alpha-1 (VII) chain) CLIA Kit (STJC0000407)

SKU:
STJC0000407

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 18.75pg/mL
Detection Limit: 31.25~2000pg/mL
Short Description: This human COL7A1 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: COL7A1
Gene ID: 1294
Uniprot ID: CO7A1_HUMAN
Specificity: This kit recognizes Human COL7 in samples. No significant cross-reactivity or interference between Human COL7 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Post Translational Modifications Prolines at the third position of the tripeptide repeating unit (G-X-Y) are hydroxylated in some or all of the chains.
Function Stratified squamous epithelial basement membrane protein that forms anchoring fibrils which may contribute to epithelial basement membrane organization and adherence by interacting with extracellular matrix (ECM) proteins such as type IV collagen.
Protein Name Collagen Alpha-1(Vii Chain
Long-Chain Collagen
Lc Collagen
Database Links Reactome: R-HSA-1442490
Reactome: R-HSA-1474244
Reactome: R-HSA-1650814
Reactome: R-HSA-2022090
Reactome: R-HSA-204005
Reactome: R-HSA-216083
Reactome: R-HSA-2214320
Reactome: R-HSA-3000157
Reactome: R-HSA-5694530
Reactome: R-HSA-8948216
Cellular Localisation Secreted
Extracellular Space
Extracellular Matrix
Basement Membrane
Alternative CLIA Names Collagen Alpha-1(Vii Chain CLIA kit
Long-Chain Collagen CLIA kit
Lc Collagen CLIA kit
COL7A1 CLIA kit
Specificity This kit recognizes Human COL7 in samples. No significant cross-reactivity or interference between Human COL7 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 87-101 92
EDTA plasma(n=8) 98-114 105
Cell culture media(n=8) 85-101 92

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 99.67 298.14 708.17 105.25 327.56 674.86
Standard deviation 10.81 21.14 68.48 12.86 29.68 51.36
CV (%) 10.85 7.09 9.67 12.22 9.06 7.61
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance