• Rat TAT (Thrombin-Antithrombin Complex) CLIA Kit (STJC0001904)

Rat TAT (Thrombin-Antithrombin Complex) CLIA Kit (STJC0001904)

SKU:
STJC0001904

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Rat
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 37.5pg/mL
Detection Limit: 62.5~4000pg/mL
Short Description: This rat TAT kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: Tat
Gene ID: 24813
Uniprot ID: ATTY_RAT
Specificity: This kit recognizes Rat TAT in samples. No significant cross-reactivity or interference between Rat TAT and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Liver.
Function Transaminase involved in tyrosine breakdown. Converts tyrosine to p-hydroxyphenylpyruvate. Can catalyze the reverse reaction, using glutamic acid, with 2-oxoglutarate as cosubstrate (in vitro). Has much lower affinity and transaminase activity towards phenylalanine.
Protein Name Tyrosine Aminotransferase
Tat
L-Tyrosine -2-Oxoglutarate Aminotransferase
Database Links Reactome: R-RNO-8963684
Alternative CLIA Names Tyrosine Aminotransferase CLIA kit
Tat CLIA kit
L-Tyrosine -2-Oxoglutarate Aminotransferase CLIA kit
Tat CLIA kit
Specificity This kit recognizes Rat TAT in samples. No significant cross-reactivity or interference between Rat TAT and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 91-105 96
EDTA plasma(n=8) 100-117 107
Cell culture media(n=8) 90-103 95

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 209.06 545.43 1341.66 196.47 567.36 1329.34
Standard deviation 24.15 42.00 100.89 23.99 45.22 128.15
CV (%) 11.55 7.70 7.52 12.21 7.97 9.64
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance