| Applications: | ELISA |
| Reactivity: | Rat |
| Note: | FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
| Sensitivity: | 7.5pg/mL |
| Detection Limit: | 12.5~800pg/mL |
| Short Description : | This Il6 Sandwich ELISA is an in-vitro enzyme-linked immunosorbent assay for the measurement of samples in rat serum, plasma and other biological fluids. |
| Storage Instruction: | If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
| Assay Time: | 3.5h |
| Detection: | Colormetric |
| Gene Symbol: | Il6 |
| Gene ID: | 24498 |
| Uniprot ID: | IL6_RAT |
| Specificity: | This kit recognizes Rat IL-6 in samples. No significant cross-reactivity or interference between Rat IL-6 and analogues was observed. |
| Sample Type: | Serum, plasma and other biological fluids |
| Protein Name | Interleukin-6Il-6 |
| Database Links | Reactome: R-RNO-1059683Reactome: -RNO-110056Reactome: -RNO-112411Reactome: -RNO-381426Reactome: -RNO-8957275 |
| Cellular Localisation | Secreted |
| Alternative ELISA Names | Interleukin-6 ELISA kitIl-6 ELISA kitIl6 ELISA kitIl-6 ELISA kit |
| Specificity | This kit recognizes Rat IL-6 in samples. No significant cross-reactivity or interference between Rat IL-6 and analogues was observed. |
| Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
| Item | Specifications | Storage |
|---|---|---|
| Micro ELISA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
| Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
| Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
| Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
| Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
| Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
| HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
| Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
| Substrate Reagent | 1 vial, 10 mL | 2-8℃ (Protect from light) |
| Stop Solution | 1 vial, 10 mL | 2-8°C |
| Plate Sealer | 5 pieces | |
| Manual | 1 copy | |
| Certificate of Analysis | 1 copy |
| Sample Type | Range (%) | Average Recovery (%) |
|---|---|---|
| Serum(n=8) | 98-111 | 105 |
| EDTA plasma (n=8) | 95-109 | 102 |
| Cell culture media (n=8) | 89-95 | 92 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision | |
|---|---|---|---|---|---|---|
| Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
| n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
| Mean (pg/mL) | 34.58 | 93.20 | 396.79 | 34.39 | 95.73 | 379.80 |
| Standard deviation | 2.04 | 4.50 | 19.96 | 1.75 | 4.79 | 18.61 |
| CV (%) | 5.90 | 4.83 | 5.03 | 5.09 | 5.00 | 4.90 |