Applications: |
CLIA |
Reactivity: |
Mouse |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
0.94ng/mL |
Detection Limit: |
1.56~100ng/mL |
Short Description: |
This mouse TTR kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes. |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
Assay Time: |
3.5h |
Detection: |
Chemiluminescence |
Gene Symbol: |
Ttr |
Gene ID: |
22139 |
Uniprot ID: |
TTHY_MOUSE |
Specificity: |
This kit recognizes Mouse TTR in samples. No significant cross-reactivity or interference between Mouse TTR and analogues was observed. |
Sample Type: |
Serum, plasma and other biological fluids |
Tissue Specificity | Detected in plasma (at protein level). Detected in liver. |
Post Translational Modifications | Sulfonation of the reactive cysteine Cys-30 enhances the stability of the native conformation of TTR, avoiding misassembly of the protein leading to amyloid formation. |
Function | Thyroid hormone-binding protein. Probably transports thyroxine from the bloodstream to the brain. |
Protein Name | TransthyretinPrealbumin |
Database Links | Reactome: R-MMU-2453902Reactome: -MMU-6798695Reactome: -MMU-975634 |
Cellular Localisation | Secreted |
Alternative CLIA Names | Transthyretin CLIA kitPrealbumin CLIA kitTtr CLIA kit |
Specificity | This kit recognizes Mouse TTR in samples. No significant cross-reactivity or interference between Mouse TTR and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro CLIA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent A | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Substrate Reagent B | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 86-101 | 92 |
EDTA plasma(n=8) | 99-112 | 104 |
Cell culture media(n=8) | 98-112 | 105 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (ng/mL) | 4.81 | 8.74 | 35.15 | 4.42 | 8.49 | 37.81 |
Standard deviation | 0.52 | 1.04 | 2.58 | 0.43 | 0.89 | 3.55 |
CV (%) | 10.81 | 11.90 | 7.34 | 9.73 | 10.48 | 9.39 |
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance