Applications: |
CLIA |
Reactivity: |
Human |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
37.5pg/mL |
Detection Limit: |
62.5~4000pg/mL |
Short Description: |
This human S100A11 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes. |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
Assay Time: |
3.5h |
Detection: |
Chemiluminescence |
Gene Symbol: |
S100A11 |
Gene ID: |
6282 |
Uniprot ID: |
S10AB_HUMAN |
Specificity: |
This kit recognizes Human S100A11 in samples. No significant cross-reactivity or interference between Human S100A11 and analogues was observed. |
Sample Type: |
Serum, plasma and other biological fluids |
Post Translational Modifications | Phosphorylation at Thr-10 by PRKCA significantly suppresses homodimerization and promotes association with NCL/nucleolin which induces nuclear translocation. |
Function | Facilitates the differentiation and the cornification of keratinocytes. |
Protein Name | Protein S100-A11CalgizzarinMetastatic Lymph Node Gene 70 ProteinMln 70Protein S100-CS100 Calcium-Binding Protein A11 Cleaved Into - Protein S100-A11 - N-Terminally Processed |
Database Links | Reactome: R-HSA-6798695 |
Cellular Localisation | CytoplasmNucleus |
Alternative CLIA Names | Protein S100-A11 CLIA kitCalgizzarin CLIA kitMetastatic Lymph Node Gene 70 Protein CLIA kitMln 70 CLIA kitProtein S100-C CLIA kitS100 Calcium-Binding Protein A11 Cleaved Into - Protein S100-A11 - N-Terminally Processed CLIA kitS100A11 CLIA kitMLN70 CLIA kitS100C CLIA kit |
Specificity | This kit recognizes Human S100A11 in samples. No significant cross-reactivity or interference between Human S100A11 and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro CLIA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent A | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Substrate Reagent B | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 96-109 | 102 |
EDTA plasma(n=8) | 91-106 | 99 |
Cell culture media(n=8) | 93-107 | 101 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (pg/mL) | 218.13 | 537.35 | 1645.33 | 238.26 | 510.96 | 1712.52 |
Standard deviation | 21.97 | 56.80 | 148.41 | 27.23 | 40.06 | 132.72 |
CV (%) | 10.07 | 10.57 | 9.02 | 11.43 | 7.84 | 7.75 |
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance