• Human EDN1 (Endothelin-1) CLIA Kit (STJC0000059)

Human EDN1 (Endothelin-1) CLIA Kit (STJC0000059)

SKU:
STJC0000059

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 4.69pg/mL
Detection Limit: 7.81~500pg/mL
Short Description: This human EDN1 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: EDN1
Gene ID: 1906
Uniprot ID: EDN1_HUMAN
Specificity: This kit recognizes Human ET-1 in samples. No significant cross-reactivity or interference between Human ET-1 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Expressed in lung, placental stem villi vessels and in cultured placental vascular smooth muscle cells.
Function Endothelins are endothelium-derived vasoconstrictor peptides. Probable ligand for G-protein coupled receptors EDNRA and EDNRB which activates PTK2B, BCAR1, BCAR3 and, GTPases RAP1 and RHOA cascade in glomerular mesangial cells. Also binds the DEAR/FBXW7-AS1 receptor.
Protein Name Endothelin-1
Preproendothelin-1
Ppet1 Cleaved Into - Endothelin-1
Et-1 - Big Endothelin-1
Database Links Reactome: R-HSA-375276
Reactome: R-HSA-416476
Cellular Localisation Secreted
Alternative CLIA Names Endothelin-1 CLIA kit
Preproendothelin-1 CLIA kit
Ppet1 Cleaved Into - Endothelin-1 CLIA kit
Et-1 - Big Endothelin-1 CLIA kit
EDN1 CLIA kit
Specificity This kit recognizes Human ET-1 in samples. No significant cross-reactivity or interference between Human ET-1 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 102-117 108
EDTA plasma(n=8) 96-107 101
Cell culture media(n=8) 101-115 106

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 22.86 62.35 206.66 23.83 67.80 198.69
Standard deviation 2.46 6.53 20.48 2.29 7.92 16.23
CV (%) 10.76 10.47 9.91 9.61 11.68 8.17
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance