• Human CRP (C-reactive protein) CLIA Kit (STJC0000039)

Human CRP (C-reactive protein) CLIA Kit (STJC0000039)

SKU:
STJC0000039

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 0.19ng/mL
Detection Limit: 0.31~20ng/mL
Short Description: This human CRP kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: CRP
Gene ID: 1401
Uniprot ID: CRP_HUMAN
Specificity: This kit recognizes Human CRP in samples. No significant cross-reactivity or interference between Human CRP and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Found in plasma.
Function Displays several functions associated with host defense: it promotes agglutination, bacterial capsular swelling, phagocytosis and complement fixation through its calcium-dependent binding to phosphorylcholine. Can interact with DNA and histones and may scavenge nuclear material released from damaged circulating cells.
Protein Name C-Reactive Protein Cleaved Into - C-Reactive Protein(1-205
Database Links Reactome: R-HSA-173623
Cellular Localisation Secreted
Alternative CLIA Names C-Reactive Protein Cleaved Into - C-Reactive Protein(1-205 CLIA kit
CRP CLIA kit
PTX1 CLIA kit
Specificity This kit recognizes Human CRP in samples. No significant cross-reactivity or interference between Human CRP and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 87-98 92
EDTA plasma(n=8) 98-110 104
Cell culture media(n=8) 88-100 93

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (ng/mL) 0.91 3.08 7.60 0.82 3.31 7.08
Standard deviation 0.11 0.35 0.66 0.09 0.27 0.53
CV (%) 12.09 11.36 8.68 10.98 8.16 7.49
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance