Tissue Specificity | Liver and plasma. |
Post Translational Modifications | Phosphorylated by FAM20C in the extracellular medium. |
Function | Minor apolipoprotein mainly associated with HDL and to a lesser extent with VLDL. May also be associated with chylomicrons. Important determinant of plasma triglyceride (TG) levels by both being a potent stimulator of apo-CII lipoprotein lipase (LPL) TG hydrolysis and an inhibitor of the hepatic VLDL-TG production rate (without affecting the VLDL-apoB production rate). Activates poorly lecithin:cholesterol acyltransferase (LCAT) and does not enhance efflux of cholesterol from macrophages. Binds heparin. |
Protein Name | Apolipoprotein A-VApo-AvApoa-VApolipoprotein A5Regeneration-Associated Protein 3 |
Database Links | Reactome: R-HSA-1989781Reactome: R-HSA-381426Reactome: R-HSA-8957275Reactome: R-HSA-8963889Reactome: R-HSA-8963901 |
Cellular Localisation | SecretedEarly EndosomeLate EndosomeGolgi ApparatusTrans-Golgi NetworkIn The Presence Of Sorl1Internalized To Early EndosomesSorted In A Retrograde Fashion To Late EndosomesFrom Which A Portion Is Sent To Lysosomes And DegradationAnother Portion Is Sorted To The Trans-Golgi Network |
Alternative CLIA Names | Apolipoprotein A-V CLIA kitApo-Av CLIA kitApoa-V CLIA kitApolipoprotein A5 CLIA kitRegeneration-Associated Protein 3 CLIA kitAPOA5 CLIA kitRAP3 CLIA kitUNQ411 CLIA kitPRO773 CLIA kit |
Specificity | This kit recognizes Human ApoA5 in samples. No significant cross-reactivity or interference between Human ApoA5 and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro CLIA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent A | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Substrate Reagent B | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 89-104 | 95 |
EDTA plasma(n=8) | 95-111 | 102 |
Cell culture media(n=8) | 85-99 | 92 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (pg/mL) | 52.16 | 143.55 | 426.29 | 50.48 | 156.60 | 412.39 |
Standard deviation | 6.22 | 15.75 | 27.37 | 4.74 | 13.56 | 42.72 |
CV (%) | 11.92 | 10.97 | 6.42 | 9.39 | 8.66 | 10.36 |