|  Post Translational Modifications  |   Phosphorylation sites are present in the extracellular medium.  |  
  |  Function  |   May have a role in chylomicrons and VLDL secretion and catabolism. Required for efficient activation of lipoprotein lipase by ApoC-II.potent activator of LCAT. Apoa-IV is a major component of HDL and chylomicrons.  |  
  |  Protein Name  |   Apolipoprotein A-IvApo-AivApoa-IvApolipoprotein A4  |  
  |  Database Links  |   Reactome: R-HSA-8963888Reactome: R-HSA-8963889Reactome: R-HSA-8963901Reactome: R-HSA-975634Reactome: R-HSA-977225  |  
  |  Cellular Localisation  |   Secreted  |  
  |  Alternative ELISA Names  |   Apolipoprotein A-Iv ELISA kitApo-Aiv ELISA kitApoa-Iv ELISA kitApolipoprotein A4 ELISA kitAPOA4 ELISA kit  |  
  |  Specificity  |   This kit recognizes Human ApoA4 in samples. No significant cross-reactivity or interference between Human ApoA4 and analogues was observed.  |  
  |  Reproducibility  |   Both intra-CV and inter-CV are  |  
 
Information sourced from Uniprot.org
   |  Item  |   Specifications  |   Storage  |  
  |  Micro ELISA Plate (Dismountable)  |   96T: 8 wells ×12 strips strips  |   -20℃, 6 months  |  
  |  Reference Standard  |   96T: 2 vials 48T: 1 vial  |   -20℃, 6 months  |  
  |  Concentrated Biotinylated Detection Ab (100×)  |   96T: 1 vial, 120 μL 60 μL  |   -20℃, 6 months  |  
  |  Concentrated HRP Conjugate (100×)  |   96T: 1 vial, 120 μL 60 μL  |   -20℃ (Protect from light), 6 months  |  
  |  Reference Standard & Sample Diluent  |   1 vial, 20 mL  |   2-8°C, 6 months  |  
  |  Biotinylated Detection Ab Diluent  |   1 vial, 14 mL  |   2-8°C, 6 months  |  
  |  HRP Conjugate Diluent  |   1 vial, 14 mL  |   2-8°C, 6 months  |  
  |  Concentrated Wash Buffer (25×)  |   1 vial, 30 mL  |   2-8°C, 6 months  |  
  |  Substrate Reagent  |   1 vial, 10 mL  |   2-8℃ (Protect from light)  |  
  |  Stop Solution  |   1 vial, 10 mL  |   2-8°C  |  
  |  Plate Sealer  |   5 pieces  |    |  
  |  Manual  |   1 copy  |    |  
  |  Certificate of Analysis  |   1 copy  |    |  
 
   |  Sample Type  |   Range (%)  |   Average Recovery (%)  |  
  |  Serum(n=8)  |   90-102  |   95  |  
  |  EDTA plasma (n=8)  |   88-102  |   95  |  
  |  Cell culture media (n=8)  |   90-103  |   95  |  
 
   |   |   Intra-assay Precision  |   Intra-assay Precision  |   Intra-assay Precision  |   Inter-assay Precision  |   Inter-assay Precision  |   Inter-assay Precision  |  
  |  Sample  |   1.00  |   2.00  |   3.00  |   1.00  |   2.00  |   3.00  |  
  |  n  |   20.00  |   20.00  |   20.00  |   20.00  |   20.00  |   20.00  |  
  |  Mean (ng/mL)  |   14.00  |   45.80  |   115.80  |   12.70  |   47.40  |   118.00  |  
  |  Standard deviation  |   0.90  |   2.50  |   3.90  |   0.80  |   2.50  |   5.80  |  
  |  CV (%)  |   6.43  |   5.46  |   3.37  |   6.30  |   5.27  |   4.92  |