• Human ALDOA (Fructose-bisphosphate aldolase A) CLIA Kit (STJC0000192)

Human ALDOA (Fructose-bisphosphate aldolase A) CLIA Kit (STJC0000192)

SKU:
STJC0000192

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 9.38pg/mL
Detection Limit: 15.63~1000pg/mL
Short Description: This human ALDOA kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: ALDOA
Gene ID: 226
Uniprot ID: ALDOA_HUMAN
Specificity: This kit recognizes Human ALDOA in samples. No significant cross-reactivity or interference between Human ALDOA and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Function Catalyzes the reversible conversion of beta-D-fructose 1,6-bisphosphate (FBP) into two triose phosphate and plays a key role in glycolysis and gluconeogenesis. In addition, may also function as scaffolding protein.
Protein Name Fructose-Bisphosphate Aldolase A
Lung Cancer Antigen Ny-Lu-1
Muscle-Type Aldolase
Database Links Reactome: R-HSA-114608
Reactome: R-HSA-6798695
Reactome: R-HSA-70171
Reactome: R-HSA-70263
Cellular Localisation Cytoplasm
Myofibril
Sarcomere
I Band
M Line
In Skeletal Muscle
Accumulates Around The M Line And Within The I Band
Colocalizing With Fbp2 On Both Sides Of The Z Line In The Absence Of Ca(2+)
Alternative CLIA Names Fructose-Bisphosphate Aldolase A CLIA kit
Lung Cancer Antigen Ny-Lu-1 CLIA kit
Muscle-Type Aldolase CLIA kit
ALDOA CLIA kit
ALDA CLIA kit
Specificity This kit recognizes Human ALDOA in samples. No significant cross-reactivity or interference between Human ALDOA and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 96-108 102
EDTA plasma(n=8) 94-109 100
Cell culture media(n=8) 97-115 105

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 53.21 146.44 357.42 53.66 159.56 364.82
Standard deviation 6.12 12.65 38.85 6.26 17.52 32.10
CV (%) 11.50 8.64 10.87 11.67 10.98 8.80
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance