Applications: |
CLIA |
Reactivity: |
Rat |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
75pg/mL |
Detection Limit: |
125~8000pg/mL |
Short Description: |
This rat F10 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes. |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
Assay Time: |
3.5h |
Detection: |
Chemiluminescence |
Gene Symbol: |
F10 |
Gene ID: |
29243 |
Uniprot ID: |
FA10_RAT |
Specificity: |
This kit recognizes Rat F10 in samples. No significant cross-reactivity or interference between Rat F10 and analogues was observed. |
Sample Type: |
Serum, plasma and other biological fluids |
Tissue Specificity | Plasma.synthesized in the liver. |
Post Translational Modifications | The vitamin K-dependent, enzymatic carboxylation of some glutamate residues allows the modified protein to bind calcium. N- and O-glycosylated. Proteolytically cleaved and activated by cathepsin CTSG. The activation peptide is cleaved by factor IXa (in the intrinsic pathway), or by factor VIIa (in the extrinsic pathway). The iron and 2-oxoglutarate dependent 3-hydroxylation of aspartate and asparagine is (R) stereospecific within EGF domains. |
Function | Factor Xa is a vitamin K-dependent glycoprotein that converts prothrombin to thrombin in the presence of factor Va, calcium and phospholipid during blood clotting. |
Protein Name | Coagulation Factor XStuart Factor Cleaved Into - Factor X Light Chain - Factor X Heavy Chain - Activated Factor Xa Heavy Chain |
Database Links | Reactome: R-RNO-140834Reactome: -RNO-140837Reactome: -RNO-140875Reactome: -RNO-159740Reactome: -RNO-159763Reactome: -RNO-159782 |
Cellular Localisation | Secreted |
Alternative CLIA Names | Coagulation Factor X CLIA kitStuart Factor Cleaved Into - Factor X Light Chain - Factor X Heavy Chain - Activated Factor Xa Heavy Chain CLIA kitF10 CLIA kit |
Specificity | This kit recognizes Rat F10 in samples. No significant cross-reactivity or interference between Rat F10 and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro CLIA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent A | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Substrate Reagent B | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 89-102 | 95 |
EDTA plasma(n=8) | 89-103 | 95 |
Cell culture media(n=8) | 87-99 | 92 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (pg/mL) | 442.82 | 1252.08 | 3842.61 | 413.70 | 1166.91 | 3760.41 |
Standard deviation | 36.84 | 98.29 | 410.39 | 51.71 | 108.76 | 399.73 |
CV (%) | 8.32 | 7.85 | 10.68 | 12.50 | 9.32 | 10.63 |
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance