Applications: |
CLIA |
Reactivity: |
Mouse |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
37.5ng/mL |
Detection Limit: |
62.5~4000ng/mL |
Short Description: |
This mouse F10 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes. |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
Assay Time: |
3.5h |
Detection: |
Chemiluminescence |
Gene Symbol: |
F10 |
Gene ID: |
14058 |
Uniprot ID: |
FA10_MOUSE |
Specificity: |
This kit recognizes Mouse F10 in samples. No significant cross-reactivity or interference between Mouse F10 and analogues was observed. |
Sample Type: |
Serum, plasma and other biological fluids |
Tissue Specificity | Plasma.synthesized in the liver. |
Post Translational Modifications | The vitamin K-dependent, enzymatic carboxylation of some glutamate residues allows the modified protein to bind calcium. N- and O-glycosylated. Proteolytically cleaved and activated by cathepsin CTSG. The activation peptide is cleaved by factor IXa (in the intrinsic pathway), or by factor VIIa (in the extrinsic pathway). |
Function | Factor Xa is a vitamin K-dependent glycoprotein that converts prothrombin to thrombin in the presence of factor Va, calcium and phospholipid during blood clotting. |
Protein Name | Coagulation Factor XStuart Factor Cleaved Into - Factor X Light Chain - Factor X Heavy Chain - Activated Factor Xa Heavy Chain |
Database Links | Reactome: R-MMU-140834Reactome: -MMU-140837Reactome: -MMU-140875Reactome: -MMU-159740Reactome: -MMU-159763Reactome: -MMU-159782 |
Cellular Localisation | Secreted |
Alternative CLIA Names | Coagulation Factor X CLIA kitStuart Factor Cleaved Into - Factor X Light Chain - Factor X Heavy Chain - Activated Factor Xa Heavy Chain CLIA kitF10 CLIA kit |
Specificity | This kit recognizes Mouse F10 in samples. No significant cross-reactivity or interference between Mouse F10 and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro CLIA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent A | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Substrate Reagent B | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 84-98 | 91 |
EDTA plasma(n=8) | 95-109 | 102 |
Cell culture media(n=8) | 97-110 | 103 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (ng/mL) | 183.85 | 525.73 | 1892.66 | 170.18 | 509.31 | 2018.86 |
Standard deviation | 19.27 | 51.31 | 201.19 | 17.41 | 54.85 | 210.37 |
CV (%) | 10.48 | 9.76 | 10.63 | 10.23 | 10.77 | 10.42 |
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance