• Rat MT1 (Metallothionein1) CLIA Kit (STJC0001808)

Rat MT1 (Metallothionein1) CLIA Kit (STJC0001808)

SKU:
STJC0001808

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Rat
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 7.5pg/mL
Detection Limit: 12.5~800pg/mL
Short Description: This rat MT1 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: Mt1
Gene ID: 24567
Uniprot ID: MT1_RAT
Specificity: This kit recognizes Rat MT1 in samples. No significant cross-reactivity or interference between Rat MT1 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Function Metallothioneins have a high content of cysteine residues that bind various heavy metals.these proteins are transcriptionally regulated by both heavy metals and glucocorticoids.
Protein Name Metallothionein-1
Mt-1
Metallothionein-I
Mt-I
Database Links Reactome: R-RNO-5661231
Alternative CLIA Names Metallothionein-1 CLIA kit
Mt-1 CLIA kit
Metallothionein-I CLIA kit
Mt-I CLIA kit
Mt1 CLIA kit
Mt1a CLIA kit
Specificity This kit recognizes Rat MT1 in samples. No significant cross-reactivity or interference between Rat MT1 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 88-104 95
EDTA plasma(n=8) 91-105 98
Cell culture media(n=8) 87-102 94

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 42.97 96.19 395.86 46.23 95.43 364.89
Standard deviation 3.85 10.62 42.16 3.86 7.06 30.58
CV (%) 8.96 11.04 10.65 8.35 7.40 8.38
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance