Applications: |
CLIA |
Reactivity: |
Mouse |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
75pg/mL |
Detection Limit: |
125~8000pg/mL |
Short Description: |
This mouse SYP kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes. |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
Assay Time: |
3.5h |
Detection: |
Chemiluminescence |
Gene Symbol: |
Syp |
Gene ID: |
20977 |
Uniprot ID: |
SYPH_MOUSE |
Specificity: |
This kit recognizes Mouse SYP in samples. No significant cross-reactivity or interference between Mouse SYP and analogues was observed. |
Sample Type: |
Serum, plasma and other biological fluids |
Post Translational Modifications | Ubiquitinated.mediated by SIAH1 or SIAH2 and leading to its subsequent proteasomal degradation. Phosphorylated by SRC. |
Function | Possibly involved in structural functions as organizing other membrane components or in targeting the vesicles to the plasma membrane. Involved in the regulation of short-term and long-term synaptic plasticity. |
Protein Name | SynaptophysinBm89 AntigenMajor Synaptic Vesicle Protein P38 |
Cellular Localisation | Cytoplasmic VesicleSecretory VesicleSynaptic Vesicle MembraneMulti-Pass Membrane ProteinSynapseSynaptosome |
Alternative CLIA Names | Synaptophysin CLIA kitBm89 Antigen CLIA kitMajor Synaptic Vesicle Protein P38 CLIA kitSyp CLIA kit |
Specificity | This kit recognizes Mouse SYP in samples. No significant cross-reactivity or interference between Mouse SYP and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro CLIA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent A | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Substrate Reagent B | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 99-114 | 105 |
EDTA plasma(n=8) | 94-108 | 102 |
Cell culture media(n=8) | 96-114 | 104 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (pg/mL) | 407.71 | 817.29 | 3022.90 | 415.86 | 894.81 | 3042.83 |
Standard deviation | 46.19 | 93.66 | 235.18 | 49.36 | 105.59 | 190.48 |
CV (%) | 11.33 | 11.46 | 7.78 | 11.87 | 11.80 | 6.26 |
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance