• Mouse SELP (P-Selectin) CLIA Kit (STJC0001285)

Mouse SELP (P-Selectin) CLIA Kit (STJC0001285)

SKU:
STJC0001285

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Mouse
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 18.75pg/mL
Detection Limit: 31.25~2000pg/mL
Short Description: This mouse SELP kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: Selp
Gene ID: 20344
Uniprot ID: LYAM3_MOUSE
Specificity: This kit recognizes Mouse SELP in samples. No significant cross-reactivity or interference between Mouse SELP and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Stored in the alpha-granules of platelets and Weibel-Palade bodies of endothelial cells. Upon cell activation by agonists, P-selectin is transported rapidly to the cell surface.
Function Ca(2+)-dependent receptor for myeloid cells that binds to carbohydrates on neutrophils and monocytes. Mediates the interaction of activated endothelial cells or platelets with leukocytes. The ligand recognized is sialyl-Lewis X. Mediates rapid rolling of leukocyte rolling over vascular surfaces during the initial steps in inflammation through interaction with SELPLG.
Protein Name P-Selectin
Cd62 Antigen-Like Family Member P
Granule Membrane Protein 140
Gmp-140
Leukocyte-Endothelial Cell Adhesion Molecule 3
Lecam3
Platelet Activation Dependent Granule-External Membrane Protein
Padgem
Cd Antigen Cd62p
Database Links Reactome: R-MMU-114608
Reactome: -MMU-202733
Cellular Localisation Cell Membrane
Single-Pass Type I Membrane Protein
Alternative CLIA Names P-Selectin CLIA kit
Cd62 Antigen-Like Family Member P CLIA kit
Granule Membrane Protein 140 CLIA kit
Gmp-140 CLIA kit
Leukocyte-Endothelial Cell Adhesion Molecule 3 CLIA kit
Lecam3 CLIA kit
Platelet Activation Dependent Granule-External Membrane Protein CLIA kit
Padgem CLIA kit
Cd Antigen Cd62p CLIA kit
Selp CLIA kit
Grmp CLIA kit
Specificity This kit recognizes Mouse SELP in samples. No significant cross-reactivity or interference between Mouse SELP and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 90-100 95
EDTA plasma(n=8) 95-113 103
Cell culture media(n=8) 97-113 104

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 107.03 172.97 752.06 110.30 189.16 701.74
Standard deviation 13.24 19.27 62.65 9.14 18.75 55.72
CV (%) 12.37 11.14 8.33 8.29 9.91 7.94
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance