Applications: |
ELISA |
Reactivity: |
Human |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
46.88pg/mL |
Detection Limit: |
78.13~5000pg/mL |
Short Description: |
This RLN1 Sandwich ELISA is an in-vitro enzyme-linked immunosorbent assay for the measurement of samples in human serum, plasma and other biological fluids. |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
Assay Time: |
3.5h |
Detection: |
Colormetric |
Gene Symbol: |
RLN1 |
Gene ID: |
6013 |
Uniprot ID: |
REL1_HUMAN |
Specificity: |
This kit recognizes Human RLN1 in samples. No significant cross-reactivity or interference between Human RLN1 and analogues was observed. |
Sample Type: |
Serum, plasma and other biological fluids |
Function | Relaxin is an ovarian hormone that acts with estrogen to produce dilatation of the birth canal in many mammals. May be involved in remodeling of connective tissues during pregnancy, promoting growth of pubic ligaments and ripening of the cervix. |
Protein Name | Prorelaxin H1 Cleaved Into - Relaxin B Chain - Relaxin A Chain |
Cellular Localisation | Secreted |
Alternative ELISA Names | Prorelaxin H1 Cleaved Into - Relaxin B Chain - Relaxin A Chain ELISA kitRLN1 ELISA kit |
Specificity | This kit recognizes Human RLN1 in samples. No significant cross-reactivity or interference between Human RLN1 and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro ELISA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent | 1 vial, 10 mL | 2-8℃ (Protect from light) |
Stop Solution | 1 vial, 10 mL | 2-8°C |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 92-105 | 97 |
EDTA plasma (n=8) | 91-101 | 96 |
Cell culture media (n=8) | 88-103 | 95 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (pg/mL) | 276.66 | 569.76 | 1772.44 | 273.10 | 552.21 | 1854.12 |
Standard deviation | 14.08 | 26.15 | 85.79 | 16.55 | 23.19 | 86.03 |
CV (%) | 5.09 | 4.59 | 4.84 | 6.06 | 4.20 | 4.64 |
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance