• Human LGALS3BP (Galectin-3-binding protein) CLIA Kit (STJC0000655)

Human LGALS3BP (Galectin-3-binding protein) CLIA Kit (STJC0000655)

SKU:
STJC0000655

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 0.19ng/mL
Detection Limit: 0.31~20ng/mL
Short Description: This human LGALS3BP kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: LGALS3BP
Gene ID: 3959
Uniprot ID: LG3BP_HUMAN
Specificity: This kit recognizes Human LGALS3BP in samples. No significant cross-reactivity or interference between Human LGALS3BP and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Ubiquitous. Detected in body fluids such as semen, milk, serum, tears, saliva and urine. Expressed by keratinocytes and fibroblasts.
Function Promotes integrin-mediated cell adhesion. May stimulate host defense against viruses and tumor cells.
Protein Name Galectin-3-Binding Protein
Basement Membrane Autoantigen P105
Lectin Galactoside-Binding Soluble 3-Binding Protein
Mac-2-Binding Protein
Mac2bp
Mac-2 Bp
Tumor-Associated Antigen 90k
Database Links Reactome: R-HSA-114608
Cellular Localisation Secreted
Extracellular Space
Extracellular Matrix
Alternative CLIA Names Galectin-3-Binding Protein CLIA kit
Basement Membrane Autoantigen P105 CLIA kit
Lectin Galactoside-Binding Soluble 3-Binding Protein CLIA kit
Mac-2-Binding Protein CLIA kit
Mac2bp CLIA kit
Mac-2 Bp CLIA kit
Tumor-Associated Antigen 90k CLIA kit
LGALS3BP CLIA kit
M2BP CLIA kit
Specificity This kit recognizes Human LGALS3BP in samples. No significant cross-reactivity or interference between Human LGALS3BP and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 85-98 91
EDTA plasma(n=8) 93-107 98
Cell culture media(n=8) 99-114 107

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (ng/mL) 0.95 2.89 9.45 0.99 2.97 9.80
Standard deviation 0.09 0.25 0.88 0.13 0.25 0.72
CV (%) 9.47 8.65 9.31 13.13 8.42 7.35
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance