Applications: |
CLIA |
Reactivity: |
Human |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
18.75pg/mL |
Detection Limit: |
31.25~2000pg/mL |
Short Description: |
This human RBP3 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes. |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
Assay Time: |
3.5h |
Detection: |
Chemiluminescence |
Gene Symbol: |
RBP3 |
Gene ID: |
5949 |
Uniprot ID: |
RET3_HUMAN |
Specificity: |
This kit recognizes Human RBP3 in samples. No significant cross-reactivity or interference between Human RBP3 and analogues was observed. |
Sample Type: |
Serum, plasma and other biological fluids |
Function | IRBP shuttles 11-cis and all trans retinoids between the retinol isomerase in the pigment epithelium and the visual pigments in the photoreceptor cells of the retina. |
Protein Name | Retinol-Binding Protein 3Interphotoreceptor Retinoid-Binding ProteinIrbpInterstitial Retinol-Binding Protein |
Database Links | Reactome: R-HSA-2187335Reactome: R-HSA-2453902 |
Cellular Localisation | SecretedExtracellular SpaceExtracellular MatrixInterphotoreceptor MatrixInterphotoreceptor Matrix That Permeates The Space Between The Retina And The Contiguous Layer Of Pigment Epithelium Cells |
Alternative CLIA Names | Retinol-Binding Protein 3 CLIA kitInterphotoreceptor Retinoid-Binding Protein CLIA kitIrbp CLIA kitInterstitial Retinol-Binding Protein CLIA kitRBP3 CLIA kit |
Specificity | This kit recognizes Human RBP3 in samples. No significant cross-reactivity or interference between Human RBP3 and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro CLIA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent A | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Substrate Reagent B | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 84-98 | 90 |
EDTA plasma(n=8) | 91-104 | 98 |
Cell culture media(n=8) | 84-98 | 91 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (pg/mL) | 102.55 | 239.14 | 966.55 | 100.15 | 218.15 | 878.45 |
Standard deviation | 12.15 | 27.98 | 58.19 | 11.70 | 20.81 | 77.39 |
CV (%) | 11.85 | 11.70 | 6.02 | 11.68 | 9.54 | 8.81 |
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance