Applications: |
CLIA |
Reactivity: |
Human |
Note: |
FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS. |
Sensitivity: |
37.5pg/mL |
Detection Limit: |
62.5~4000pg/mL |
Short Description: |
This human LDLR kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes. |
Storage Instruction: |
If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual. |
Assay Time: |
3.5h |
Detection: |
Chemiluminescence |
Gene Symbol: |
LDLR |
Gene ID: |
3949 |
Uniprot ID: |
LDLR_HUMAN |
Specificity: |
This kit recognizes Human LDLR in samples. No significant cross-reactivity or interference between Human LDLR and analogues was observed. |
Sample Type: |
Serum, plasma and other biological fluids |
Post Translational Modifications | N- and O-glycosylated. Ubiquitinated by MYLIP leading to degradation. |
Function | Binds LDL, the major cholesterol-carrying lipoprotein of plasma, and transports it into cells by endocytosis. In order to be internalized, the receptor-ligand complexes must first cluster into clathrin-coated pits. (Microbial infection) Acts as a receptor for hepatitis C virus in hepatocytes, but not through a direct interaction with viral proteins. (Microbial infection) Acts as a receptor for Vesicular stomatitis virus. (Microbial infection) In case of HIV-1 infection, may function as a receptor for extracellular Tat in neurons, mediating its internalization in uninfected cells. |
Protein Name | Low-Density Lipoprotein ReceptorLdl Receptor |
Database Links | Reactome: R-HSA-8856825Reactome: R-HSA-8856828Reactome: R-HSA-8964026Reactome: R-HSA-8964038Reactome: R-HSA-975634 |
Cellular Localisation | Cell MembraneSingle-Pass Type I Membrane ProteinMembraneClathrin-Coated PitGolgi ApparatusEarly EndosomeLate EndosomeLysosomeRapidly Endocytosed Upon Ligand Binding |
Alternative CLIA Names | Low-Density Lipoprotein Receptor CLIA kitLdl Receptor CLIA kitLDLR CLIA kit |
Specificity | This kit recognizes Human LDLR in samples. No significant cross-reactivity or interference between Human LDLR and analogues was observed. |
Reproducibility | Both intra-CV and inter-CV are |
Information sourced from Uniprot.org
Item | Specifications | Storage |
Micro CLIA Plate (Dismountable) | 96T: 8 wells ×12 strips strips | -20℃, 6 months |
Reference Standard | 96T: 2 vials 48T: 1 vial | -20℃, 6 months |
Concentrated Biotinylated Detection Ab (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃, 6 months |
Concentrated HRP Conjugate (100×) | 96T: 1 vial, 120 μL 60 μL | -20℃ (Protect from light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 2-8°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
HRP Conjugate Diluent | 1 vial, 14 mL | 2-8°C, 6 months |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | 2-8°C, 6 months |
Substrate Reagent A | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Substrate Reagent B | 1 vial, 5 mL | 2-8℃ (Protect from light) |
Plate Sealer | 5 pieces | |
Manual | 1 copy | |
Certificate of Analysis | 1 copy | |
Sample Type | Range (%) | Average Recovery (%) |
Serum(n=8) | 99-114 | 107 |
EDTA plasma(n=8) | 90-103 | 97 |
Cell culture media(n=8) | 83-96 | 90 |
| Intra-assay Precision | Intra-assay Precision | Intra-assay Precision | Inter-assay Precision | Inter-assay Precision | Inter-assay Precision |
Sample | 1.00 | 2.00 | 3.00 | 1.00 | 2.00 | 3.00 |
n | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 | 20.00 |
Mean (pg/mL) | 189.01 | 335.31 | 1502.02 | 205.60 | 310.76 | 1626.23 |
Standard deviation | 20.79 | 26.15 | 146.15 | 20.17 | 36.55 | 153.84 |
CV (%) | 11.00 | 7.80 | 9.73 | 9.81 | 11.76 | 9.46 |
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance