• Human CLC (Galectin-10) CLIA Kit (STJC0000679)

Human CLC (Galectin-10) CLIA Kit (STJC0000679)

SKU:
STJC0000679

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 18.75pg/mL
Detection Limit: 31.25~2000pg/mL
Short Description: This human CLC kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: CLC
Gene ID: 1178
Uniprot ID: LEG10_HUMAN
Specificity: This kit recognizes Human CLC in samples. No significant cross-reactivity or interference between Human CLC and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Expressed abundantly in the bone marrow. Expressed exclusively by eosinophils and basophils. Not detected in monocytes and neutrophils. Expressed in CD25-positive regulatory T-cells (Treg) (at protein level). Found in intestinal tissue from patients with Celiac disease, expression is directly related to the histological grade of mucosal damage and to the number of eosinophils found in the duodenal lesion (at protein level). Found in sputum of patients with eosinophilic inflammatory diseases such as asthma (at protein level).
Function Regulates immune responses through the recognition of cell-surface glycans. Essential for the anergy and suppressive function of CD25-positive regulatory T-cells (Treg).
Protein Name Galectin-10
Gal-10
Charcot-Leyden Crystal Protein
Clc
Eosinophil Lysophospholipase
Lysolecithin Acylhydrolase
Cellular Localisation Cytoplasm
Cytosol
Cytoplasmic Granule
Localized In Granules From Where It May Be Secreted Or Transported To Other Locations In The Cell
Alternative CLIA Names Galectin-10 CLIA kit
Gal-10 CLIA kit
Charcot-Leyden Crystal Protein CLIA kit
Clc CLIA kit
Eosinophil Lysophospholipase CLIA kit
Lysolecithin Acylhydrolase CLIA kit
CLC CLIA kit
LGALS10 CLIA kit
LGALS10A CLIA kit
Specificity This kit recognizes Human CLC in samples. No significant cross-reactivity or interference between Human CLC and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 89-104 95
EDTA plasma(n=8) 89-103 96
Cell culture media(n=8) 94-106 100

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 102.59 225.87 935.82 112.07 246.17 927.38
Standard deviation 13.28 24.73 102.10 9.84 22.25 81.24
CV (%) 12.94 10.95 10.91 8.78 9.04 8.76
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance