• Human A1-AT (Alpha 1-Antitrypsin) CLIA Kit (STJC0000476)

Human A1-AT (Alpha 1-Antitrypsin) CLIA Kit (STJC0000476)

SKU:
STJC0000476

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 0.38ng/mL
Detection Limit: 0.63~40ng/mL
Short Description: This human A1-AT kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Specificity: This kit recognizes Human Alpha 1-AT in samples. No significant cross-reactivity or interference between Human Alpha 1-AT and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Specificity This kit recognizes Human α1-AT in samples. No significant cross-reactivity or interference between Human α1-AT and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 89-102 95
EDTA plasma(n=8) 88-99 93
Cell culture media(n=8) 98-115 106

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (ng/mL) 1.89 5.72 18.29 1.95 5.87 16.92
Standard deviation 0.18 0.65 1.46 0.24 0.44 1.62
CV (%) 9.52 11.36 7.98 12.31 7.50 9.57
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance