• Rat TACR1 (Tachykinin Receptor 1) CLIA Kit (STJC0001894)

Rat TACR1 (Tachykinin Receptor 1) CLIA Kit (STJC0001894)

SKU:
STJC0001894

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Rat
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 18.75pg/mL
Detection Limit: 31.25~2000pg/mL
Short Description: This rat TACR1 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: Tacr1
Gene ID: 24807
Uniprot ID: NK1R_RAT
Specificity: This kit recognizes Rat TACR1 in samples. No significant cross-reactivity or interference between Rat TACR1 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Function This is a receptor for the tachykinin neuropeptide substance P. It is probably associated with G proteins that activate a phosphatidylinositol-calcium second messenger system. The rank order of affinity of this receptor to tachykinins is: substance P > substance K > neuromedin-K.
Protein Name Substance-P Receptor
Spr
Nk-1 Receptor
Nk-1r
Tachykinin Receptor 1
Database Links Reactome: R-RNO-380095
Reactome: -RNO-416476
Reactome: -RNO-8856825
Reactome: -RNO-8856828
Cellular Localisation Cell Membrane
Multi-Pass Membrane Protein
Alternative CLIA Names Substance-P Receptor CLIA kit
Spr CLIA kit
Nk-1 Receptor CLIA kit
Nk-1r CLIA kit
Tachykinin Receptor 1 CLIA kit
Tacr1 CLIA kit
Tac1r CLIA kit
Specificity This kit recognizes Rat TACR1 in samples. No significant cross-reactivity or interference between Rat TACR1 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 100-113 106
EDTA plasma(n=8) 83-95 90
Cell culture media(n=8) 94-110 101

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 108.21 295.83 708.96 117.30 278.85 662.17
Standard deviation 12.83 26.15 73.38 14.39 19.58 59.53
CV (%) 11.86 8.84 10.35 12.27 7.02 8.99
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance