• Rat NGB (Neuroglobin) CLIA Kit (STJC0001815)

Rat NGB (Neuroglobin) CLIA Kit (STJC0001815)

SKU:
STJC0001815

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Rat
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 4.69pg/mL
Detection Limit: 7.81~500pg/mL
Short Description: This rat NGB kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: Ngb
Gene ID: 85382
Uniprot ID: NGB_RAT
Specificity: This kit recognizes Rat NGB in samples. No significant cross-reactivity or interference between Rat NGB and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Widely distributed throughout the adult brain, including cerebral cortex, hippocampus, thalamus, hypothalamus, olfactory bulb, and cerebellum.
Function Involved in oxygen transport in the brain. Hexacoordinate globin, displaying competitive binding of oxygen or the distal His residue to the iron atom. Not capable of penetrating cell membranes.
Protein Name Neuroglobin
Database Links Reactome: R-RNO-8981607
Cellular Localisation Perikaryon
Alternative CLIA Names Neuroglobin CLIA kit
Ngb CLIA kit
Specificity This kit recognizes Rat NGB in samples. No significant cross-reactivity or interference between Rat NGB and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 102-116 108
EDTA plasma(n=8) 102-115 107
Cell culture media(n=8) 97-113 103

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 23.88 60.46 242.09 21.77 57.43 241.87
Standard deviation 3.01 5.37 21.62 2.05 6.43 16.28
CV (%) 12.60 8.88 8.93 9.42 11.20 6.73
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance