• Rat MHC 1/AgB 1/H-11 (Major Histocompatibility Complex 1) CLIA Kit (STJC0001793)

Rat MHC 1/AgB 1/H-11 (Major Histocompatibility Complex 1) CLIA Kit (STJC0001793)

SKU:
STJC0001793

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Rat
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 1.13pg/mL
Detection Limit: 1.88~120pg/mL
Short Description: This rat MHC 1/AgB 1/H-11 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Specificity: This kit recognizes Rat MHC 1/AgB 1/H-1 1 in samples. No significant cross-reactivity or interference between Rat MHC 1/AgB 1/H-1 1 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Specificity This kit recognizes Rat MHCⅠ/AgBⅠ/H-1Ⅰ in samples. No significant cross-reactivity or interference between Rat MHCⅠ/AgBⅠ/H-1Ⅰ and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 85-97 91
EDTA plasma(n=8) 99-116 107
Cell culture media(n=8) 91-107 97

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 5.79 12.53 52.32 5.37 11.77 52.63
Standard deviation 0.60 1.14 5.01 0.55 0.96 5.77
CV (%) 10.36 9.10 9.58 10.24 8.16 10.96
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance