• Rat Calca (Calcitonin) Sandwich ELISA (STJE0005456)

Rat Calca (Calcitonin) Sandwich ELISA (STJE0005456)

SKU:
STJE0005456

Shipping:
Free Shipping
Current Stock:
Applications: ELISA
Reactivity: Rat
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 9.38pg/mL
Detection Limit: 15.63~1000pg/mL
Short Description: This Calca Sandwich ELISA is an in-vitro enzyme-linked immunosorbent assay for the measurement of samples in rat cell culture supernatant, serum and plasma (EDTA, citrate, heparin).
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Colormetric
Gene Symbol: Calca
Gene ID: 24241
Uniprot ID: CALC_RAT
Specificity: This kit recognizes Rat CT in samples. No significant cross-reactivity or interference between Rat CT and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Protein Name Calcitonin
Database Links
Reactome: R-RNO-419812
Cellular Localisation Secreted
Alternative ELISA Names Calcitonin ELISA kit
Calca ELISA kit
Calc ELISA kit
Specificity This kit recognizes Rat CT in samples. No significant cross-reactivity or interference between Rat CT and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro ELISA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent 1 vial, 10 mL 2-8℃ (Protect from light)
Stop Solution 1 vial, 10 mL 2-8°C
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 92-105 99
EDTA plasma (n=8) 86-98 93
Cell culture media (n=8) 91-102 96

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 46.60 124.20 434.20 49.80 113.70 400.00
Standard deviation 2.70 6.10 19.10 3.00 5.20 14.80
CV (%) 5.79 4.91 4.40 6.02 4.57 3.70