• Mouse ECM1 (Extracellular Matrix Protein 1) CLIA Kit (STJC0001212)

Mouse ECM1 (Extracellular Matrix Protein 1) CLIA Kit (STJC0001212)

SKU:
STJC0001212

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Mouse
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 4.69pg/mL
Detection Limit: 7.81~500pg/mL
Short Description: This mouse ECM1 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: Ecm1
Gene ID: 13601
Uniprot ID: ECM1_MOUSE
Specificity: This kit recognizes Mouse ECM1 in samples. No significant cross-reactivity or interference between Mouse ECM1 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Tissue Specificity Expressed in the surrounding connective tissues of developing long bones, but not in the cartilage. The long isoform is expressed in a number of tissues including liver, heart and lungs. The short isoform is expressed in skin and cartilage-containing tissues such as tail and front paw. No expression is found in brain.
Function Involved in endochondral bone formation as negative regulator of bone mineralization. Stimulates the proliferation of endothelial cells and promotes angiogenesis. Inhibits MMP9 proteolytic activity.
Protein Name Extracellular Matrix Protein 1
Secretory Component P85
Database Links Reactome: R-MMU-114608
Cellular Localisation Secreted
Extracellular Space
Extracellular Matrix
Alternative CLIA Names Extracellular Matrix Protein 1 CLIA kit
Secretory Component P85 CLIA kit
Ecm1 CLIA kit
Specificity This kit recognizes Mouse ECM1 in samples. No significant cross-reactivity or interference between Mouse ECM1 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 99-113 105
EDTA plasma(n=8) 87-103 94
Cell culture media(n=8) 97-109 103

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 26.76 48.78 204.32 26.21 52.31 222.36
Standard deviation 3.24 5.80 18.98 2.20 4.17 24.33
CV (%) 12.11 11.89 9.29 8.39 7.97 10.94