• Human TNNT1 (Troponin T, slow skeletal muscle) CLIA Kit (STJC0000673)

Human TNNT1 (Troponin T, slow skeletal muscle) CLIA Kit (STJC0000673)

SKU:
STJC0000673

Shipping:
Free Shipping
Current Stock:
Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 4.69pg/mL
Detection Limit: 7.81~500pg/mL
Short Description: This human TNNT1 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Gene Symbol: TNNT1
Gene ID: 7138
Uniprot ID: TNNT1_HUMAN
Specificity: This kit recognizes Human TNNT1 in samples. No significant cross-reactivity or interference between Human TNNT1 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Function Troponin T is the tropomyosin-binding subunit of troponin, the thin filament regulatory complex which confers calcium-sensitivity to striated muscle actomyosin ATPase activity.
Protein Name Troponin T - Slow Skeletal Muscle
Tnts
Slow Skeletal Muscle Troponin T
Stnt
Database Links Reactome: R-HSA-390522
Alternative CLIA Names Troponin T - Slow Skeletal Muscle CLIA kit
Tnts CLIA kit
Slow Skeletal Muscle Troponin T CLIA kit
Stnt CLIA kit
TNNT1 CLIA kit
TNT CLIA kit
Specificity This kit recognizes Human TNNT1 in samples. No significant cross-reactivity or interference between Human TNNT1 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 90-103 96
EDTA plasma(n=8) 99-116 106
Cell culture media(n=8) 89-100 94

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 27.60 53.79 166.94 28.19 50.86 174.29
Standard deviation 3.07 3.79 12.89 3.33 4.87 15.22
CV (%) 11.12 7.05 7.72 11.81 9.58 8.73
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance